----------------------- EasySet readme ------------------------ _______________________________________________________________ *** Activate the "Word Wrap" option in Notepad and try changing the font and font size (e.g. Arial 8) to make this readme file easier to read. _______________________________________________________________ *** For additional product-specific readme information, refer to the readme file for your product in your EasySet directory. _______________________________________________________________ ============ INSTALLATION ============ IMPORTANT: Installing to the same directory as a previous version of EasySet will uninstall the previous version. If you want to keep your previous version of EasySet as well as the new version, rename your existing EasySet directory before you install the new version. The following products are not included in this install package: - MaxiScan 1000, MaxiScan 2100, MaxiScan 2200, MaxiScan 3010, MaxiScan 3100, MaxiScan 3300 If your product is in this list, install EasySet and copy the corresponding product setup files (available from the Intermec downloads website) to your newly installed EasySet directory. The installation package cleans up unnecessary registry entries from previous versios (HKCU) and updates the registry with new entries (HKLM) --------------------------------------------------------------- EasySet and WinFlash --------------------------------------------------------------- - the latest version of WinFlash (Intermec firmware download wizard) is included in the EasySet installation package and can be run from inside EasySet ("Tools - Upgrade product firmware" menu option) - EasySet and WinFlash can be installed and run independently - the latest versions of EasySet and WinFlash can be downloaded from: http://www.intermec.com --------------------------------------------------------------- EasySet and the SF51 Firmware Upgrade Utility --------------------------------------------------------------- - the latest version of the SF51 Firmware Upgrade Utility (Intermec firmware download wizard for the SF51) is included in the EasySet installation package and can be run from inside EasySet ("Tools - Upgrade product firmware" menu option) - EasySet and the SF51 Firmware Upgrade Utility can be installed and run independently - the latest versions of EasySet and the SF51 Firmware Upgrade Utility can be downloaded from: http://www.intermec.com --------------------------------------------------------------- Windows Installer --------------------------------------------------------------- - the setup.exe package for EasySet will install MSI 2.0 (Windows Installer) or later if not already installed (the system may need to be restarted for Windows Installer to be updated) - for Windows NT4 platforms: MSI 2.0 requires SP6, MSI 1.2 requires SP3 - OS-specific versions of the Windows Installer are available from http://www.microsoft.com/downloads --------------------------------------------------------------- Uninstall issues --------------------------------------------------------------- 1 : Uninstall does not remove new files added after the initial installation (EasySet ".cfg" files, terminal selector database files, "easyset.gid" Help file, user-created files, ...) Workaround : These files and the EasySet directory must be removed manually if you wish to uninstall completely 2 : In addition to the above files, uninstall of EasySet may not remove certain files incorrectly installed as refcounted shared files with previous versions of EasySet (easyset.exe, easyset.hlp, editing4.exe) Workaround: Ask your Systems Engineer to remove the references to these files in the Windows registry under: [HKEY_LOCAL_MACHINE]\SOFTWARE\Microsoft\Windows\Current Version\SharedDLLs\[INSTALLDIR]\file_names In this case you may also have to manually remove the EasySet shortcuts (Start menu, desktop). --------------------------------------------------------------- Adding deprecated products --------------------------------------------------------------- - In Easyset.ini, you will find all deprecated products that are not visible in the product selector. - To add these old products, you should find the product line with product name under[Products] entry. - Then delete the word "LegacyProduct" in the product line. _______________________________________________________________ _______________________________________________________________ EasySet - Version 5.6.5.4 (20 Nov 2012) _______________________________________________________________ ===================== Plugin / DLL versions ===================== - Interlink.exe - 2.08 << New version Intermec Download Firmware - ISCP_cmd_set.chm - 2.1 ISCP online help file - ISDC_ActiveSync.dll - 1.3.5.0 ActiveSync interface DLL - ISDC_BT.dll - 1.0.0.5 Bluetooth interface DLL - ISDC_Rs.dll - 2.5.4.0 RS serial interface DLL - ISDC_Usb.dll - 1.1.4.1 USB interface DLL - ISDC_HID.dll - 1.0.8.0 << New version USB Keyboard DLL - ISDC_PNP.dll - 1.0.2.0 Plug and play DLL - StcImageData.dll - 2.0.0.0 Image Data DLL - ConfigGen.dll - 1.0.0.3 Barcode generation DLL - Upgrade.exe - 2.2.0.0 Intermec SR61T download firmware - UpgradeTransportSelect.exe - 1.0.0.1 Intermec scanner selection for SR61 firmware upgrade - Winflash.msi - 3.1.1.6 << New version Intermec Scanner upgrade firmware - VCP_Setup.msi - 1.0.04 << Added Intermec scanners virtual com port driver ===================== Additional file versions ===================== - iscp.iscp ISCP commands file for ISCP Terminal database - EasySet.INI ============================ IMPROVEMENTS / NEW FEATURES ============================ ---------------------------------------------------------------- Ability to change Ready to work LED color on SR61B ---------------------------------------------------------------- ---------------------------------------------------------------- Ability to change communication timeouts ---------------------------------------------------------------- ---------------------------------------------------------------- Changing to upload complete scanner configuration ---------------------------------------------------------------- ---------------------------------------------------------------- BugFix: MB9730 communication menu invisible ---------------------------------------------------------------- ---------------------------------------------------------------- Simplified video window ---------------------------------------------------------------- ---------------------------------------------------------------- Bugfix: Data editing: replace a string by an empty string ---------------------------------------------------------------- ---------------------------------------------------------------- BugFix: Image conditioning maximum width and height ---------------------------------------------------------------- ---------------------------------------------------------------- Changing Easyset icon ---------------------------------------------------------------- ---------------------------------------------------------------- Adding new product: EV14 scan engine ---------------------------------------------------------------- ---------------------------------------------------------------- _______________________________________________________________ EasySet - Version 5.6.5.3 (19 Jun 2012) _______________________________________________________________ ===================== Plugin / DLL versions ===================== - Interlink.exe - 0 2 4 1 _ 2 06 Intermec Download Firmware - ISCP_cmd_set.chm - 2.1 ISCP online help file - ISDC_ActiveSync.dll - 1.3.5.0 ActiveSync interface DLL - ISDC_BT.dll - 1.0.0.5 Bluetooth interface DLL - ISDC_Rs.dll - 2.5.4.0 RS serial interface DLL - ISDC_Usb.dll - 1.1.4.1 USB interface DLL - ISDC_HID.dll - 1.0.6.0 USB Keyboard DLL - ISDC_PNP.dll - 1.0.2.0 Plug and play DLL - StcImageData.dll - 2.0.0.0 Image Data DLL - ConfigGen.dll - 1.0.0.3 Barcode generation DLL - Upgrade.exe - 2.2.0.0 Intermec SR61T download firmware - UpgradeTransportSelect.exe - 1.0.0.1 Intermec scanner selection for SR61 firmware upgrade - Winflash.msi - 3.1.1.6 << New version Intermec Scanner upgrade firmware - VCP_Setup.msi - 1.0.04 << Added Intermec scanners virtual com port driver ===================== Additional file versions ===================== - iscp.iscp ISCP commands file for ISCP Terminal database - EasySet.INI ============================ IMPROVEMENTS / NEW FEATURES ============================ ---------------------------------------------------------------- Adding new SR61B scanner ---------------------------------------------------------------- ---------------------------------------------------------------- Changing help text on product selection window ---------------------------------------------------------------- ---------------------------------------------------------------- Changing string composition window to mask extended characters when they are not allowed ---------------------------------------------------------------- ---------------------------------------------------------------- Bugfix: about window string for dll versions ---------------------------------------------------------------- ---------------------------------------------------------------- Removing languages option ---------------------------------------------------------------- ---------------------------------------------------------------- Adding menu option 'Show product selection window at startup' and 'Connection on product selection' ---------------------------------------------------------------- ---------------------------------------------------------------- Changing name of 'Print test sheet' menu to 'View test sheet (PDF Format)' ---------------------------------------------------------------- ---------------------------------------------------------------- Adding automatic VCP driver installation at first start or with menu (Options --> Launch VCP drivers installation) ---------------------------------------------------------------- _____________________________________________________________ EasySet - Version 5.6.5.1 (19 Dec 2011) _______________________________________________________________ ===================== Plugin / DLL versions ===================== - Interlink.exe - 0 2 4 1 _ 2 06 Intermec Download Firmware - ISCP_cmd_set.chm - 2.1 ISCP online help file - ISDC_ActiveSync.dll - 1.3.5.0 ActiveSync interface DLL - ISDC_BT.dll - 1.0.0.5 Bluetooth interface DLL - ISDC_Rs.dll - 2.5.4.0 >> new version RS serial interface DLL - ISDC_Usb.dll - 1.1.4.1 USB interface DLL - ISDC_HID.dll - 1.0.6.0 >> new version USB Keyboard DLL - ISDC_PNP.dll - 1.0.2.0 >> new version Plug and play DLL - StcImageData.dll - 2.0.0.0 Image Data DLL - ConfigGen.dll - 1.0.0.3 >> new version Barcode generation DLL - Upgrade.exe - 2.2.0.0 Intermec SR61T download firmware - UpgradeTransportSelect.exe - 1.0.0.1 Intermec scanner selection for SR61 firmware upgrade - Winflash.msi - 3.1.1.4 >> new version Intermec Scanner upgrade firmware ===================== Additional file versions ===================== - iscp.iscp - 2011/12/19 ISCP commands file for ISCP Terminal database - EasySet.INI - 2011/12/19 ============================ IMPROVEMENTS / NEW FEATURES ============================ ---------------------------------------------------------------- Adding new SG20 scanner ---------------------------------------------------------------- ---------------------------------------------------------------- Adding plug and play device detection ---------------------------------------------------------------- ---------------------------------------------------------------- Grey out and cross unsupported features and grey out commands for unconnected devices ---------------------------------------------------------------- ---------------------------------------------------------------- Hide ISCP menu for SG10 product ---------------------------------------------------------------- ---------------------------------------------------------------- BugFix : Video and snapshot with windows 7 ---------------------------------------------------------------- ---------------------------------------------------------------- BugFix : ISCP terminal invisible after docking ---------------------------------------------------------------- ---------------------------------------------------------------- BugFix : Custom defaults with invalid buffer ---------------------------------------------------------------- ---------------------------------------------------------------- Adding *.ini entry for restartproduct ---------------------------------------------------------------- ---------------------------------------------------------------- Adding *.ini entry for PnpName ---------------------------------------------------------------- ---------------------------------------------------------------- Adding *.ini entry for Winflash names ---------------------------------------------------------------- _______________________________________________________________ EasySet - Version 5.6.4.8 _______________________________________________________________ ===================== Plugin / DLL versions ===================== - Interlink.exe - 0 2 4 1 _ 2 06 Intermec Download Firmware - ISCP_cmd_set.chm - 2.1 ISCP online help file - ISDC_ActiveSync.dll - 1.3.5.0 ActiveSync interface DLL - ISDC_BT.dll - 1.0.0.5 Bluetooth interface DLL - ISDC_Rs.dll - 2.5.3.0 >> new version RS serial interface DLL - ISDC_Usb.dll - 1.1.4.1 USB interface DLL - ISDC_HID.dll - 1.0.5.0 >> new version USB Keyboard DLL - StcImageData.dll - 2.0.0.0 Image Data DLL - ConfigGen.dll - 1.0.0.2 Barcode generation DLL - Upgrade.exe - 2.2.0.0 Intermec SR61T download firmware - UpgradeTransportSelect.exe - 1.0.0.1 Intermec scanner selection for SR61 firmware upgrade - Winflash.msi - 3.1.1.1 Intermec Scanner upgrade firmware ===================== Additional file versions ===================== - iscp.iscp - 2011/04/19 ISCP commands file for ISCP Terminal database - EasySet.INI - 2011/09/09 ============================ IMPROVEMENTS / NEW FEATURES ============================ ---------------------------------------------------------------- Adding SG20B and SG20BS products ---------------------------------------------------------------- _______________________________________________________________ EasySet - Version 5.6.4.7 _______________________________________________________________ ===================== Plugin / DLL versions ===================== - Interlink.exe - 0 2 4 1 _ 2 06 Intermec Download Firmware - ISCP_cmd_set.chm - 2.1 ISCP online help file - ISDC_ActiveSync.dll - 1.3.5.0 ActiveSync interface DLL - ISDC_BT.dll - 1.0.0.5 Bluetooth interface DLL - ISDC_Rs.dll - 2.5.3.0 >> new version RS serial interface DLL - ISDC_Usb.dll - 1.1.4.1 USB interface DLL - ISDC_HID.dll - 1.0.5.0 >> new version USB Keyboard DLL - StcImageData.dll - 2.0.0.0 Image Data DLL - ConfigGen.dll - 1.0.0.2 Barcode generation DLL - Upgrade.exe - 2.2.0.0 Intermec SR61T download firmware - UpgradeTransportSelect.exe - 1.0.0.1 Intermec scanner selection for SR61 firmware upgrade - Winflash.msi - 3.1.1.1 Intermec Scanner upgrade firmware ===================== Additional file versions ===================== - iscp.iscp - 2011/04/19 ISCP commands file for ISCP Terminal database - EasySet.INI - 2011/09/09 ============================ IMPROVEMENTS / NEW FEATURES ============================ ---------------------------------------------------------------- Adding SG20T ---------------------------------------------------------------- ---------------------------------------------------------------- Delete barcode capabilities on SG20BS ---------------------------------------------------------------- ---------------------------------------------------------------- Changing ISDC_RS and ISDC_HID dll ---------------------------------------------------------------- ---------------------------------------------------------------- New installer uninstall automatically previous versions ---------------------------------------------------------------- ---------------------------------------------------------------- New installer check for adobe reader 9 ---------------------------------------------------------------- ---------------------------------------------------------------- Greying out the ISCP help menu on SG10 product ---------------------------------------------------------------- ______________________________________________________________ EasySet - Version 5.6.4.6 _______________________________________________________________ ===================== Plugin / DLL versions ===================== - Interlink.exe - 0 2 4 1 _ 2 06 Intermec Download Firmware - ISCP_cmd_set.chm - 2.1 ISCP online help file - ISDC_ActiveSync.dll - 1.3.5.0 ActiveSync interface DLL - ISDC_BT.dll - 1.0.0.5 Bluetooth interface DLL - ISDC_Rs.dll - 2.5.1.2 RS serial interface DLL - ISDC_Usb.dll - 1.1.4.1 USB interface DLL - ISDC_HID.dll - 1.0.4.0 USB Keyboard DLL - StcImageData.dll - 2.0.0.0 Image Data DLL - ConfigGen.dll - 1.0.0.2 Barcode generation DLL - Upgrade.exe - 2.2.0.0 Intermec SR61T download firmware - UpgradeTransportSelect.exe - 1.0.0.1 Intermec scanner selection for SR61 firmware upgrade - Winflash.msi - 3.1.1.1 Intermec Scanner upgrade firmware ===================== Additional file versions ===================== - iscp.iscp - 2011/04/19 ISCP commands file for ISCP Terminal database - EasySet.INI - 2011/04/26 ============================ IMPROVEMENTS / NEW FEATURES ============================ ---------------------------------------------------------------- Adding SG10 ---------------------------------------------------------------- _______________________________________________________________ EasySet - Version 5.6.4.4 _______________________________________________________________ ===================== Plugin / DLL versions ===================== - Interlink.exe - 0 2 4 1 _ 2 06 >>> new version Intermec Download Firmware - ISCP_cmd_set.chm - 2.1 >>> new version ISCP online help file - ISDC_ActiveSync.dll - 1.3.5.0 ActiveSync interface DLL - ISDC_BT.dll - 1.0.0.5 >>> new version Bluetooth interface DLL - ISDC_Rs.dll - 2.5.1.2 >>> new version RS serial interface DLL - ISDC_Usb.dll - 1.1.4.1 USB interface DLL - ISDC_HID.dll - 1.0.4.0 >>> new version USB Keyboard DLL - StcImageData.dll - 2.0.0.0 >>> new version Image Data DLL - ConfigGen.dll - 1.0.0.2 >>> new version Barcode generation DLL - Upgrade.exe - 2.2.0.0 Intermec SR61T download firmware - UpgradeTransportSelect.exe - 1.0.0.1 Intermec scanner selection for SR61 firmware upgrade - Winflash.msi - 3.1.1.1 Intermec Scanner upgrade firmware ===================== Additional file versions ===================== - iscp.iscp - 2011/04/19 ISCP commands file for ISCP Terminal database - EasySet.INI - 2011/04/26 ============================ IMPROVEMENTS / NEW FEATURES ============================ ---------------------------------------------------------------- Adding ability to concatenate Reset factory defaults barcodes ---------------------------------------------------------------- ---------------------------------------------------------------- Adding custom defaults and persistent data support ---------------------------------------------------------------- ---------------------------------------------------------------- Adding support for SG10 (with code 39 configuration codes) ---------------------------------------------------------------- ---------------------------------------------------------------- Adding ability to save as jpg in STCImageData ---------------------------------------------------------------- ---------------------------------------------------------------- Adding ability to generate code 39 in ConfigGen ---------------------------------------------------------------- ---------------------------------------------------------------- New names for data editing functions ---------------------------------------------------------------- ---------------------------------------------------------------- Change name of Irregular EAN to unconventional GS1-128 ---------------------------------------------------------------- _______________________________________________________________ _______________________________________________________________ EasySet - Version 5.6.4.2 _______________________________________________________________ ===================== Plugin / DLL versions ===================== - Interlink.exe - 0 2 4 1 _ 2 04 Intermec Download Firmware - ISCP_cmd_set.chm - 2.0 ISCP online help file - ISDC_ActiveSync.dll - 1.3.5.0 ActiveSync interface DLL - ISDC_BT.dll - 1.0.0.3 >>> new version Bluetooth interface DLL - ISDC_Rs.dll - 2.5.1.1 RS serial interface DLL - ISDC_Usb.dll - 1.1.4.1 USB interface DLL - ISDC_UsbKbd.dll - 1.0.2.0 >>> new version USB Keyboard DLL - StcImageData.dll - 1.0.0.5 Image Data DLL - ConfigGen.dll - 1.0.0.1 Barcode generation DLL - Upgrade.exe - 2.2.0.0 Intermec SR61T download firmware - UpgradeTransportSelect.exe - 1.0.0.1 Intermec scanner selection for SR61 firmware upgrade - Winflash.msi - 3.1.1.1 >>> new version Intermec Scanner upgrade firmware ===================== Additional file versions ===================== - iscp.iscp - 2010/09/22 ISCP commands file for ISCP Terminal database - EasySet.INI - 2010/09/22 ===================== Product setup file versions ===================== Computersen.cmd 2010/06/28 modified CN50en.cmd 2010/06/28 modified ea15en.cmd 2010/06/28 modified ev12en.cmd 2010/06/28 modified ev15en.cmd 2010/06/28 modified ex25en.cmd 2010/06/28 modified ed40en.cmd 2010/06/28 modified sr30en.cmd 2010/02/12 modified sr61en.cmd 2010/06/25 modified sr61ten.cmd 2010/09/22 added sd61en.cmd 2010/09/22 modified sf51en.cmd 2010/09/27 modified e1022en.cmd 2007/09/03 mb9730en.cmd 2008/07/03 mb9730en.cmd 2008/07/03 mb9730gm.cmd 2003/05/06 mb9730it.cmd 2003/05/06 mb9730po.cmd 2003/05/06 mb9730sp.cmd 2003/05/06 ms2210en.cmd 2006/02/24 ms2220en.cmd 2006/02/24 s1400en.cmd 2007/09/04 s1551en.cmd 2007/09/04 s1552en.cmd external product setup file s1553en.cmd 2007/09/04 s1555en.cmd 2004/12/09 si1470en.cmd external product setup file sp1800en.cmd 2007/09/04 sp1800fr.cmd 2003/05/06 sp1800gm.cmd 2003/05/06 sp1800it.cmd 2003/05/06 sp1800po.cmd 2003/05/06 sp1800sp.cmd 2003/05/06 sp1802en.cmd 2007/09/14 ============================ IMPROVEMENTS / NEW FEATURES ============================ --------------------------------------------------------------- Bugfix --> Display of barcode window --------------------------------------------------------------- --------------------------------------------------------------- Bugfix --> Long time before connection window --------------------------------------------------------------- --------------------------------------------------------------- Bugfix --> PDF417 concatenation --------------------------------------------------------------- --------------------------------------------------------------- Adding SR30 wand configuration --------------------------------------------------------------- --------------------------------------------------------------- Bugfix --> Wedge characters for data editing --------------------------------------------------------------- --------------------------------------------------------------- BugFix --> Data editing delete block --------------------------------------------------------------- --------------------------------------------------------------- Bugfix --> Snapshot --------------------------------------------------------------- --------------------------------------------------------------- Added new product (SR61T) --------------------------------------------------------------- --------------------------------------------------------------- Bugfix --> Data editing mask problem --------------------------------------------------------------- --------------------------------------------------------------- Bugfix --> Negative numbers display --------------------------------------------------------------- --------------------------------------------------------------- Bugfix --> Connection with old SR61 --------------------------------------------------------------- ---------------------------------------------------------------- Changing 128 string by ISCP string in barcode window ---------------------------------------------------------------- ---------------------------------------------------------------- Removing legacy products from product selection window ---------------------------------------------------------------- ---------------------------------------------------------------- Adding command type in get data string window ---------------------------------------------------------------- ---------------------------------------------------------------- Adding help text on ISCP terminal window ---------------------------------------------------------------- ---------------------------------------------------------------- Video menu deleted from SR30 ---------------------------------------------------------------- _______________________________________________________________ _______________________________________________________________ EasySet - Version 5.6.3.0 _______________________________________________________________ ===================== Plugin / DLL versions ===================== - Interlink.exe - 0 2 4 1 _ 2 04 Intermec Download Firmware - ISCP_cmd_set.chm - 2.0 >>> new version ISCP online help file - ISDC_ActiveSync.dll - 1.3.5.0 ActiveSync interface DLL - ISDC_BT.dll - 1.0.0.2 Bluetooth interface DLL - ISDC_Rs.dll - 2.5.1.0 >>> new version new RS serial interface DLL - ISDC_Usb.dll - 1.1.4.1 USB interface DLL - ISDC_UsbKbd.dll - 1.0.0.1 >>> new dll USB Keyboard DLL - StcImageData.dll - 1.0.0.5 Image Data DLL - Upgrade.exe - 2.2.0.0 Intermec SR61T download firmware - UpgradeTransportSelect.exe - 1.0.0.1 Intermec scanner selection for SR61 firmware upgrade - Winflash.msi - 3.1.0.9 >>> new version Intermec Scanner upgrade firmware ===================== Additional file versions ===================== - iscp.iscp - 2008/09/29 ISCP commands file for ISCP Terminal database - EasySet.INI - 2010/02/19 ===================== Product setup file versions ===================== Computersen.cmd 2010/02/19 modified CN50en.cmd 2010/02/19 added e1022en.cmd 2007/09/03 ea15en.cmd 2010/02/15 modified ev12en.cmd 2010/02/15 modified ev15en.cmd 2010/02/15 modified ex25en.cmd 2010/02/15 modified ed40en.cmd 2010/02/19 added mb9730en.cmd 2008/07/03 mb9730en.cmd 2008/07/03 mb9730gm.cmd 2003/05/06 mb9730it.cmd 2003/05/06 mb9730po.cmd 2003/05/06 mb9730sp.cmd 2003/05/06 ms2210en.cmd 2006/02/24 ms2220en.cmd 2006/02/24 s1400en.cmd 2007/09/04 s1551en.cmd 2007/09/04 s1552en.cmd external product setup file s1553en.cmd 2007/09/04 s1555en.cmd 2004/12/09 sf51en.cmd 2010/02/16 modified si1470en.cmd external product setup file sp1800en.cmd 2007/09/04 sp1800fr.cmd 2003/05/06 sp1800gm.cmd 2003/05/06 sp1800it.cmd 2003/05/06 sp1800po.cmd 2003/05/06 sp1800sp.cmd 2003/05/06 sp1802en.cmd 2007/09/14 sr30en.cmd 2010/02/12 modified sr61en.cmd 2010/02/16 modified sd61en.cmd 2010/02/16 modified ============================ IMPROVEMENTS / NEW FEATURES ============================ --------------------------------------------------------------- New SD61 interface --------------------------------------------------------------- --------------------------------------------------------------- New data editing V2 window --------------------------------------------------------------- --------------------------------------------------------------- New data editing V1 window --------------------------------------------------------------- --------------------------------------------------------------- Docked ISCP terminal for online configuration --------------------------------------------------------------- --------------------------------------------------------------- New image conditioning window --------------------------------------------------------------- --------------------------------------------------------------- Support for document capture --------------------------------------------------------------- --------------------------------------------------------------- Added new products (ED40 and CN50) --------------------------------------------------------------- _______________________________________________________________ _______________________________________________________________ EasySet - Version 5.6.2.0 _______________________________________________________________ ===================== Plugin / DLL versions ===================== - Interlink.exe - 0 2 4 1 _ 2 04 Intermec Download Firmware - ISCP_cmd_set.chm - 1.7 ISCP online help file - ISDC_ActiveSync.dll - 1.3.5.0 >>> new version ActiveSync interface DLL - ISDC_BT.dll - 1.0.0.2 Bluetooth interface DLL - ISDC_Rs.dll - 2.0.1.7 new RS serial interface DLL - ISDC_Usb.dll - 1.1.4.1 USB interface DLL - StcImageData.dll - 1.0.0.5 Image Data DLL - Upgrade.exe - 2.2.0.0 Intermec SR61T download firmware - UpgradeTransportSelect.exe - 1.0.0.1 Intermec scanner selection for SR61 firmware upgrade - Winflash.msi - 3.1.0.7 >>> new version Intermec Scanner upgrade firmware ===================== Additional file versions ===================== - iscp.iscp - 2008/09/29 ISCP commands file for ISCP Terminal database - EasySet.INI - 2009/03/17 ===================== Product setup file versions ===================== Computersen.cmd 2009/02/11 e1022en.cmd 2007/09/03 ea15en.cmd 2009/09/28 Modified ev12en.cmd 2009/01/30 ev15en.cmd 2009/01/30 ex25en.cmd 2009/09/28 Modified mb9730en.cmd 2008/07/03 mb9730en.cmd 2008/07/03 mb9730gm.cmd 2003/05/06 mb9730it.cmd 2003/05/06 mb9730po.cmd 2003/05/06 mb9730sp.cmd 2003/05/06 ms2210en.cmd 2006/02/24 ms2220en.cmd 2006/02/24 s1400en.cmd 2007/09/04 s1551en.cmd 2007/09/04 s1552en.cmd external product setup file s1553en.cmd 2007/09/04 s1555en.cmd 2004/12/09 sf51en.cmd 2009/04/08 si1470en.cmd external product setup file sp1800en.cmd 2007/09/04 sp1800fr.cmd 2003/05/06 sp1800gm.cmd 2003/05/06 sp1800it.cmd 2003/05/06 sp1800po.cmd 2003/05/06 sp1800sp.cmd 2003/05/06 sp1802en.cmd 2007/09/14 sr30en.cmd 2009/09/28 Modified sr61en.cmd 2009/04/08 sd61en.cmd 2009/10/01 Added ============================ IMPROVEMENTS / NEW FEATURES ============================ --------------------------------------------------------------- New warning message for PDF concatenation with reset factory defaults --------------------------------------------------------------- --------------------------------------------------------------- New command file for SD61 bluetooth base station --------------------------------------------------------------- --------------------------------------------------------------- Bugfix: PDF Concatenation of multiple commands --------------------------------------------------------------- --------------------------------------------------------------- Collapse tree after reset factory defaults --------------------------------------------------------------- _______________________________________________________________ _______________________________________________________________ EasySet - Version 5.6.1.0 _______________________________________________________________ ===================== Plugin / DLL versions ===================== - Interlink.exe - 0 2 4 1 _ 2 04 Intermec Download Firmware - ISCP_cmd_set.chm - 1.7 ISCP online help file - ISDC_ActiveSync.dll - 1.3.4.0 >>>new version ActiveSync interface DLL - ISDC_BT.dll - 1.0.0.2 Bluetooth interface DLL - ISDC_Rs.dll - 2.0.1.7 new RS serial interface DLL - ISDC_Usb.dll - 1.1.4.1 >>>new version USB interface DLL - StcImageData.dll - 1.0.0.5 >>> new version Image Data DLL - Upgrade.exe - 2.2.0.0 >>> new version Intermec SR61T download firmware - UpgradeTransportSelect.exe - 1.0.0.1 Intermec scanner selection for SR61 firmware upgrade - Winflash.msi - 3.1.0.6 >>> new version Intermec Scanner upgrade firmware ===================== Additional file versions ===================== - iscp.iscp - 2008/05/04 ISCP commands file for ISCP Terminal database - EasySet.INI - 2009/03/17 ===================== Product setup file versions ===================== 700cen.cmd 2007/09/04 Deleted ck30en.cmd 2007/09/04 Deleted cn3en.cmd 2007/09/04 Deleted Computersen.cmd 2009/02/11 Added e1022en.cmd 2007/09/03 ea15en.cmd 2009/02/02 Modified ev12en.cmd 2009/01/30 Modified ev15en.cmd 2009/01/30 Modified ex25en.cmd 2009/02/02 Modified mb9730en.cmd 2008/07/03 modified mb9730en.cmd 2008/07/03 mb9730gm.cmd 2003/05/06 mb9730it.cmd 2003/05/06 mb9730po.cmd 2003/05/06 mb9730sp.cmd 2003/05/06 ms2210en.cmd 2006/02/24 ms2220en.cmd 2006/02/24 s1400en.cmd 2007/09/04 s1551en.cmd 2007/09/04 s1552en.cmd external product setup file s1553en.cmd 2007/09/04 s1555en.cmd 2004/12/09 sf51en.cmd 2009/04/08 Modified si1470en.cmd external product setup file sp1800en.cmd 2007/09/04 sp1800fr.cmd 2003/05/06 sp1800gm.cmd 2003/05/06 sp1800it.cmd 2003/05/06 sp1800po.cmd 2003/05/06 sp1800sp.cmd 2003/05/06 sp1802en.cmd 2007/09/14 sr30en.cmd 2009/03/17 Modified sr61en.cmd 2009/04/08 Modified ============================ IMPROVEMENTS / NEW FEATURES ============================ --------------------------------------------------------------- New error message for old winflash versions --------------------------------------------------------------- --------------------------------------------------------------- Get Data String Window --------------------------------------------------------------- - The Get Data String Window didn't appears on first time click --------------------------------------------------------------- Code Mark --------------------------------------------------------------- - Code Mark was not read --------------------------------------------------------------- BitField Window created for unconventional 128 --------------------------------------------------------------- - New parameter with 3 bitfields --------------------------------------------------------------- Specials wedge characters window --------------------------------------------------------------- - This window appeared when not wanted --------------------------------------------------------------- Main window appeared between two screens on first open --------------------------------------------------------------- --------------------------------------------------------------- PDF417 configuration codes (only for ISCP products) --------------------------------------------------------------- - Available after BF2_048_ for EA15 and EX25 - Available after A41P116_ for EV15 --------------------------------------------------------------- Unable to define a pause of 1 second during wedge transmission --------------------------------------------------------------- - BugFix on pause definition --------------------------------------------------------------- Unable to load command files on windows xp china (bad checksum) --------------------------------------------------------------- - BugFix on checksum calculation --------------------------------------------------------------- Generic command files for computers --------------------------------------------------------------- - All computers (CN3,CK31...) have now the same command file --------------------------------------------------------------- New Version of Upgrade.exe --------------------------------------------------------------- - Software to download SR61T --------------------------------------------------------------- Removing jpeg saving on STCimage --------------------------------------------------------------- - Not possible to save as jpeg on video window --------------------------------------------------------------- Removing old help files --------------------------------------------------------------- - Help file for EasySet was obsolete --------------------------------------------------------------- Change on events display on hexadecimal --------------------------------------------------------------- - All Events were not displayed correctly --------------------------------------------------------------- Compose string --------------------------------------------------------------- - Bugfix with size of ISCP string when compose only one character --------------------------------------------------------------- Adding a thread to receive image data --------------------------------------------------------------- - In EasySet 5.6.0.0 when receiving image data, the application froze --------------------------------------------------------------- Bugfix on multicode mask compose --------------------------------------------------------------- _______________________________________________________________ _______________________________________________________________ EasySet - Version 5.6.0.0 _______________________________________________________________ ===================== Plugin / DLL versions ===================== - Interlink.exe - 0 2 4 1 _ 2 04 - ISCP_cmd_set.chm - 1.7 >>> new version ISCP online help file - ISDC_ActiveSync.dll - 1.2.0.3 ActiveSync interface DLL - ISDC_BT.dll - 1.0.0.2 Bluetooth interface DLL - ISDC_Rs.dll - 2.0.1.7 >>> new version new RS serial interface DLL - ISDC_Usb.dll - 1.1.4.0 USB interface DLL - STCDecodesDll.dll - 1.0.5.3 Intermec decode dll >>> added DLL - StcImageData.dll - 1.0.0.2 >>> new version Image Data DLL - Upgrade.exe - 1.0.0.1 - UpgradeTransportSelect.exe - 1.0.0.1 - Winflash.msi - 3.1.0.1 >>> new version WinFlash firmware download plugin ===================== Additional file versions ===================== - iscp.iscp - 2008/03/18 ISCP commands file for ISCP Terminal database - EasySet.INI >>modified ===================== Product setup file versions ===================== 700cen.cmd 2007/09/04 ck30en.cmd 2007/09/04 cn3en.cmd 2007/09/04 e1022en.cmd 2007/09/03 ea15en.cmd 2008/09/05 modified ev12en.cmd 2007/09/03 ev15en.cmd 2007/09/03 ex25en.cmd 2008/09/05 modified mb9730en.cmd 2008/07/03 modified mb9730en.cmd 1999/11/15 mb9730gm.cmd 1999/11/15 mb9730it.cmd 1999/11/15 mb9730po.cmd 1999/11/15 mb9730sp.cmd 1999/11/15 ms2210en.cmd 2006/02/24 ms2220en.cmd 2006/02/24 s1400en.cmd 2007/09/04 s1551en.cmd 2007/09/04 s1552en.cmd external product setup file s1553en.cmd 2007/09/04 s1555en.cmd 2004/12/09 sf51en.cmd 2008/04/08 modified si1470en.cmd external product setup file sp1800en.cmd 2007/09/04 sp1800fr.cmd 2003/03/28 sp1800gm.cmd 1999/09/01 sp1800it.cmd 1999/09/01 sp1800po.cmd 1999/09/01 sp1800sp.cmd 1999/09/01 sp1802en.cmd 2007/09/04 sr30en.cmd 2008/09/15 modified sr61en.cmd 2008/04/08 modified ============================ IMPROVEMENTS / NEW FEATURES ============================ --------------------------------------------------------------- Message dialog in English --------------------------------------------------------------- - All message dialogs displayed in English --------------------------------------------------------------- Special keys between [ ] --------------------------------------------------------------- - New special keys notation --------------------------------------------------------------- Help Message for [Enter] special key --------------------------------------------------------------- --------------------------------------------------------------- Upgrade display of wedge keys for virtual tree --------------------------------------------------------------- - The display of keys is different between wedge products and RS232 products --------------------------------------------------------------- Verify version number of Winflash to download SR30 --------------------------------------------------------------- - To download SR30 you need to choose the HIP or scan engine 1d or 2d. The older versions of Winflash can't download SR30 --------------------------------------------------------------- Add an additional button on video mode --------------------------------------------------------------- - Press this button to launch video mode and enable the decode --------------------------------------------------------------- Add a bigger buffer for video operations --------------------------------------------------------------- - Add a buffer of 1024000 Bytes (resolution of EA21 (future product)) --------------------------------------------------------------- Display change for icons --------------------------------------------------------------- --------------------------------------------------------------- Integration of events management --------------------------------------------------------------- - Management of all types of events with display (on ISCP terminal) --------------------------------------------------------------- New Keyboard Wedge Specifications --------------------------------------------------------------- - This version supports new keyboard wedge specifications (use a 255 character table) + special keys --------------------------------------------------------------- Delete error messages when setup read not available for product --------------------------------------------------------------- - Before this version, when you send an unavailable command you see error messages --------------------------------------------------------------- Integration of messages for video --------------------------------------------------------------- - When you open video window, you must be in packeted data - When you take a snapshot or a video, it will be long if image data is not on JPEG --------------------------------------------------------------- Sending Silent mode off after abort done received --------------------------------------------------------------- - We now send Silent mode Off after abort done frame received --------------------------------------------------------------- "Continuous video on / off" option --------------------------------------------------------------- - requests continuous video images from the scanner - "Take snapshot" is not enabled when "Continuous video on" mode is activated --------------------------------------------------------------- EasySet.ini file update --------------------------------------------------------------- - SR30, EX25, EA15 and SR61 are considered as video products - New Winflash version --------------------------------------------------------------- Update Winflash Version --------------------------------------------------------------- --------------------------------------------------------------- Messages for progression on video window --------------------------------------------------------------- --------------------------------------------------------------- New command files for SR30, SR61 and 9730 --------------------------------------------------------------- --------------------------------------------------------------- Don't display the error number for dll error --------------------------------------------------------------- _______________________________________________________________ _______________________________________________________________ EasySet - Version 5.5.0.0 _______________________________________________________________ ===================== Plugin / DLL versions ===================== - Interlink.exe - 0 2 4 1 _ 2 04 - ISCP_cmd_set.chm - 1.6 >>> new version ISCP online help file - IscpRsPlugin.dll - 1.0.3.4 >>> supprimé old RS serial interface DLL - ISDC_ActiveSync.dll - 1.2.0.3 >>> new DLL ActiveSync interface DLL - ISDC_BT.dll - 1.0.0.2 >>> new DLL new Bluetooth interface DLL - ISDC_Rs.dll - 2.0.1.2 >>> new version RS serial interface DLL - ISDC_Usb.dll - 1.1.4.0 >>> new DLL new USB interface DLL - SF51.dll - 9.9.0.0 >>> supprimé old Bluetooth interface DLL - SF51Upgrade.exe - 1.0.3.161 >>> supprimé SF51 Firmware Upgrade Utility - StcImageData.dll - 1.0.0.1 >>> new DLL new imaging and video DLL - Upgrade.exe - 1.0.0.1 >>> new exe file - UpgradeTransportSelect.exe - 1.0.0.1 >>> new exe file - Winflash.msi - 3.0.9.8 >>> new version WinFlash firmware download plugin ===================== Additional file versions ===================== - iscp.iscp - 2008/03/18 ISCP commands file for ISCP Terminal database ===================== Product setup file versions ===================== 700cen.cmd 2007/09/04 ck30en.cmd 2007/09/04 cn3en.cmd 2007/09/04 e1022en.cmd 2007/09/03 ea15en.cmd 2008/06/26 modified ev12en.cmd 2007/09/03 ev15en.cmd 2007/09/03 ex25en.cmd 2008/06/26 modified mb9730en.cmd 2006/02/17 mb9730en.cmd 1999/11/15 mb9730gm.cmd 1999/11/15 mb9730it.cmd 1999/11/15 mb9730po.cmd 1999/11/15 mb9730sp.cmd 1999/11/15 ms2210en.cmd 2006/02/24 ms2220en.cmd 2006/02/24 s1400en.cmd 2007/09/04 s1551en.cmd 2007/09/04 s1552en.cmd external product setup file s1553en.cmd 2007/09/04 s1555en.cmd 2004/12/09 sf51en.cmd 2007/09/03 si1470en.cmd external product setup file sp1800en.cmd 2007/09/04 sp1800fr.cmd 2003/03/28 sp1800gm.cmd 1999/09/01 sp1800it.cmd 1999/09/01 sp1800po.cmd 1999/09/01 sp1800sp.cmd 1999/09/01 sp1802en.cmd 2007/09/04 sr30en.cmd 2008/06/26 modified sr61en.cmd 2008/06/26 modified ============================ IMPROVEMENTS / NEW FEATURES ============================ --------------------------------------------------------------- USB interface (SR30) --------------------------------------------------------------- - added USB interface driver to communicate with product via USB cable (SR30) --------------------------------------------------------------- Integration of video capability --------------------------------------------------------------- - added Video menu and toolbar for products which have imaging and video functionality (EA15, EX25, ...) IMPORTANT REMARKS - "PACKET" DATA FORMAT MUST BE ACTIVATED - the [Data transmission settings - ISCP - data format] setup command must be set to "packet" to enable image and video display in EasySet (tip: use the "Search" function to find the word "packet" in the commands window) IMPORTANT REMARKS - "SYNCHRONOUS" EVENT HANDLING NOT SUPPORTED IN THIS VERSION - activate [Imager settings - general - image data transmission - synchronous] for image display on scanner events (example: take snapshot on good read event) is not implemented in this version IMPORTANT REMARKS - "ASYNCHRONOUS" MODE FOR HOST OR SCANNER-INITIATED VIDEO OPERATION - activate [Imager settings - general - image data transmission - asynchronous] for image display requested by host or scanner initiated (on good read or trigger pressed for example) - activate a start condition [Imager settings - snapshot / video - start condition] to define which action on the scanner side will result in image display IMPORTANT REMARKS - EXAMPLES OF OTHER PARAMETER SETTINGS FOR COMFORTABLE SNAPSHOT / VIDEO OPERATION - adjust the following snapshot / video parameter settings (example settings) for comfortable snapshot / video viewing: - [Imager settings - snapshot / video - compression] = "JPEG" - [Imager settings - snapshot / video - compression quality] = 50 - [Imager settings - snapshot / video - resolution] = 2 --------------------------------------------------------------- "Show / Hide video window" option --------------------------------------------------------------- - displays or hides the video window in the EasySet setup sheet area - the video window must be visible to enable the other video commands REMARK: The scanner will continue to send video images if it is in "Continuous video on" mode or is sending scanner-sollicited images, even if the video window is not currently displayed. --------------------------------------------------------------- "Take snapshot" option --------------------------------------------------------------- - requests a single image from the scanner - not enabled if "Continuous video on" mode is activated REMARK: The scanner reading beam must be on to take a snapshot - you can activate the reading beam with the pushbutton in the "ISCP Terminal" window. --------------------------------------------------------------- "Continuous video on / off" option --------------------------------------------------------------- - requests continuous video images from the scanner - "Take snapshot" is not enabled when "Continuous video on" mode is activated --------------------------------------------------------------- Reset offline value fields --------------------------------------------------------------- - automatic "reset to empty" of data entry fields in offline mode for the following windows: - "preamble" - "postamble" - "compose input type" (data editing) - "compose input length" (data editing) - "compose input mask" (data editing) REMARK 1: The data editing windows display the current value in the product when they are opened in online mode REMARK 2: The "compose action list" data editing window already has this type of behavior (offline / online) REMARK 3: The "preamble" and "postamble" windows do not display the current value in the product when they are opened in online mode REMARK 4: The "compose input type" data editing window is a single-value numerical window - all other windows of this type (e.g. "compose minimum length" windows in the "Symbologies" section) now have an equivalent behavior to this window --------------------------------------------------------------- Renaming certain symbologies --------------------------------------------------------------- - currently renaming some symbologies in line with international symbology naming conventions : old name new name RSS 14 GS1 DataBar Omni-Directional RSS Limited GS1 DataBar Limited RSS Expanded GS1 DataBar Expanded EAN.UCC Composite GS1 Composite Code 128/EAN 128 Code 128/GS1-128 UPC/EAN EAN/UPC - the symbology selection lists in EasySet have been updated to reflect these changes =============================================== PROBLEM CORRECTIONS =============================================== --------------------------------------------------------------- Setup sheet position at startup --------------------------------------------------------------- - corrected position of setup sheet when EasySet is started - sheet is now correctly positioned top left with sheet title (product name by default) in view --------------------------------------------------------------- Year updated to 2008 in copyright captions --------------------------------------------------------------- - corrected year for 2008 --------------------------------------------------------------- "Invalid handle" message during online "Upgrade firmware" request --------------------------------------------------------------- - corrected "Invalid handle" problem during online "Upgrade firmware" request with "ISCP Terminal" window open ("ISCP Terminal" window is now closed when firmware upgrade is requested) --------------------------------------------------------------- Refresh commands window after "reset factory defaults except locked parameters" --------------------------------------------------------------- - corrected refresh of commands window when "reset factory defaults except locked parameters" is sent to the product (EA15, EX25, ...) in online mode _______________________________________________________________ _______________________________________________________________ EasySet - Version 5.5.0.0 _______________________________________________________________ ===================== Plugin / DLL versions ===================== - ActiveSyncISCP.dll - 1.0.0.6 >>> supprimé ActiveSync interface DLL + RAPI_API.dll (companion DLL) - Interlink.exe - 0 2 4 1 _ 2 04 - ISCP_cmd_set.chm - 1.6 >>> new version ISCP online help file - IscpRsPlugin.dll - 1.0.3.4 >>> supprimé old RS serial interface DLL - ISDC_ActiveSync.dll - 1.2.0.3 >>> new DLL ActiveSync interface DLL - ISDC_BT.dll - 1.0.0.2 >>> new DLL new Bluetooth interface DLL - ISDC_Rs.dll - 2.0.1.2 >>> new version RS serial interface DLL - ISDC_Usb.dll - 1.1.4.0 >>> new DLL new USB interface DLL - SF51.dll - 9.9.0.0 >>> supprimé old Bluetooth interface DLL - SF51Upgrade.exe - 1.0.3.161 >>> supprimé SF51 Firmware Upgrade Utility - StcImageData.dll - 1.0.0.1 >>> new DLL new imaging and video DLL - Upgrade.exe - 1.0.0.1 >>> new exe file - UpgradeTransportSelect.exe - 1.0.0.1 >>> new exe file - Winflash.msi - 3.0.9.8 >>> new version WinFlash firmware download plugin ===================== Additional file versions ===================== - iscp.iscp - 2008/03/18 ISCP commands file for ISCP Terminal database ===================== Product setup file versions ===================== 700cen.cmd 2007/09/04 ck30en.cmd 2007/09/04 cn3en.cmd 2007/09/04 e1022en.cmd 2007/09/03 ea15en.cmd 2008/06/26 modified ev12en.cmd 2007/09/03 ev15en.cmd 2007/09/03 ex25en.cmd 2008/06/26 modified mb9730en.cmd 2006/02/17 mb9730en.cmd 1999/11/15 mb9730gm.cmd 1999/11/15 mb9730it.cmd 1999/11/15 mb9730po.cmd 1999/11/15 mb9730sp.cmd 1999/11/15 ms2210en.cmd 2006/02/24 ms2220en.cmd 2006/02/24 s1400en.cmd 2007/09/04 s1551en.cmd 2007/09/04 s1552en.cmd external product setup file s1553en.cmd 2007/09/04 s1555en.cmd 2004/12/09 sf51en.cmd 2007/09/03 si1470en.cmd external product setup file sp1800en.cmd 2007/09/04 sp1800fr.cmd 2003/03/28 sp1800gm.cmd 1999/09/01 sp1800it.cmd 1999/09/01 sp1800po.cmd 1999/09/01 sp1800sp.cmd 1999/09/01 sp1802en.cmd 2007/09/04 sr30en.cmd 2008/06/26 modified sr61en.cmd 2008/06/26 modified ============================ IMPROVEMENTS / NEW FEATURES ============================ --------------------------------------------------------------- USB interface (SR30) --------------------------------------------------------------- - added USB interface driver to communicate with product via USB cable (SR30) --------------------------------------------------------------- Integration of video capability --------------------------------------------------------------- - added Video menu and toolbar for products which have imaging and video functionality (EA15, EX25, ...) IMPORTANT REMARKS - "PACKET" DATA FORMAT MUST BE ACTIVATED - the [Data transmission settings - ISCP - data format] setup command must be set to "packet" to enable image and video display in EasySet (tip: use the "Search" function to find the word "packet" in the commands window) IMPORTANT REMARKS - "SYNCHRONOUS" EVENT HANDLING NOT SUPPORTED IN THIS VERSION - activate [Imager settings - general - image data transmission - synchronous] for image display on scanner events (example: take snapshot on good read event) is not implemented in this version IMPORTANT REMARKS - "ASYNCHRONOUS" MODE FOR HOST OR SCANNER-INITIATED VIDEO OPERATION - activate [Imager settings - general - image data transmission - asynchronous] for image display requested by host or scanner initiated (on good read or trigger pressed for example) - activate a start condition [Imager settings - snapshot / video - start condition] to define which action on the scanner side will result in image display IMPORTANT REMARKS - EXAMPLES OF OTHER PARAMETER SETTINGS FOR COMFORTABLE SNAPSHOT / VIDEO OPERATION - adjust the following snapshot / video parameter settings (example settings) for comfortable snapshot / video viewing: - [Imager settings - snapshot / video - compression] = "JPEG" - [Imager settings - snapshot / video - compression quality] = 50 - [Imager settings - snapshot / video - resolution] = 2 --------------------------------------------------------------- "Show / Hide video window" option --------------------------------------------------------------- - displays or hides the video window in the EasySet setup sheet area - the video window must be visible to enable the other video commands REMARK: The scanner will continue to send video images if it is in "Continuous video on" mode or is sending scanner-sollicited images, even if the video window is not currently displayed. --------------------------------------------------------------- "Take snapshot" option --------------------------------------------------------------- - requests a single image from the scanner - not enabled if "Continuous video on" mode is activated REMARK: The scanner reading beam must be on to take a snapshot - you can activate the reading beam with the pushbutton in the "ISCP Terminal" window. --------------------------------------------------------------- "Continuous video on / off" option --------------------------------------------------------------- - requests continuous video images from the scanner - "Take snapshot" is not enabled when "Continuous video on" mode is activated --------------------------------------------------------------- Reset offline value fields --------------------------------------------------------------- - automatic "reset to empty" of data entry fields in offline mode for the following windows: - "preamble" - "postamble" - "compose input type" (data editing) - "compose input length" (data editing) - "compose input mask" (data editing) REMARK 1: The data editing windows display the current value in the product when they are opened in online mode REMARK 2: The "compose action list" data editing window already has this type of behavior (offline / online) REMARK 3: The "preamble" and "postamble" windows do not display the current value in the product when they are opened in online mode REMARK 4: The "compose input type" data editing window is a single-value numerical window - all other windows of this type (e.g. "compose minimum length" windows in the "Symbologies" section) now have an equivalent behavior to this window --------------------------------------------------------------- Renaming certain symbologies --------------------------------------------------------------- - currently renaming some symbologies in line with international symbology naming conventions : old name new name RSS 14 GS1 DataBar Omni-Directional RSS Limited GS1 DataBar Limited RSS Expanded GS1 DataBar Expanded EAN.UCC Composite GS1 Composite Code 128/EAN 128 Code 128/GS1-128 UPC/EAN EAN/UPC - the symbology selection lists in EasySet have been updated to reflect these changes =============================================== PROBLEM CORRECTIONS =============================================== --------------------------------------------------------------- Setup sheet position at startup --------------------------------------------------------------- - corrected position of setup sheet when EasySet is started - sheet is now correctly positioned top left with sheet title (product name by default) in view --------------------------------------------------------------- Year updated to 2008 in copyright captions --------------------------------------------------------------- - corrected year for 2008 --------------------------------------------------------------- "Invalid handle" message during online "Upgrade firmware" request --------------------------------------------------------------- - corrected "Invalid handle" problem during online "Upgrade firmware" request with "ISCP Terminal" window open ("ISCP Terminal" window is now closed when firmware upgrade is requested) --------------------------------------------------------------- Refresh commands window after "reset factory defaults except locked parameters" --------------------------------------------------------------- - corrected refresh of commands window when "reset factory defaults except locked parameters" is sent to the product (EA15, EX25, ...) in online mode _______________________________________________________________ _______________________________________________________________ EasySet - Version 5.4.4.0 _______________________________________________________________ ===================== Plugin / DLL versions ===================== - ActiveSyncISCP.dll - 1.0.0.6 + RAPI_API.dll ActiveSync interface DLL + companion DLL - Interlink.exe - 0 2 4 1 _ 2 04 - ISCP_cmd_set.chm - 1.5 ISCP online help file - IscpRsPlugin.dll - 1.0.3.4 old RS serial interface DLL - ISDC_Rs.dll - 1.1.0.2 new RS serial interface DLL - SF51.dll - 9.9.0.0 Bluetooth interface DLL - SF51Upgrade.exe - 1.0.3.161 SF51 Firmware Upgrade Utility - Winflash.msi - 3.0.9.5 >>> new version WinFlash firmware download plugin ===================== Product setup file versions ===================== 700cen.cmd 2007/09/04 modified ck30en.cmd 2007/09/04 modified cn3en.cmd 2007/09/04 new product e1022en.cmd 2007/09/03 modified ea15en.cmd 2007/09/04 modified ev12en.cmd 2007/09/03 modified ev15en.cmd 2007/09/03 modified ex25en.cmd 2007/09/11 modified mb9730en.cmd 2006/02/17 mb9730en.cmd 1999/11/15 mb9730gm.cmd 1999/11/15 mb9730it.cmd 1999/11/15 mb9730po.cmd 1999/11/15 mb9730sp.cmd 1999/11/15 ms2210en.cmd 2006/02/24 ms2220en.cmd 2006/02/24 s1400en.cmd 2007/09/04 modified s1551en.cmd 2007/09/04 modified s1552en.cmd external product setup file s1553en.cmd 2007/09/04 modified s1555en.cmd 2004/12/09 sf51en.cmd 2007/09/03 modified si1470en.cmd external product setup file sp1800en.cmd 2007/09/04 modified sp1800fr.cmd 2003/03/28 sp1800gm.cmd 1999/09/01 sp1800it.cmd 1999/09/01 sp1800po.cmd 1999/09/01 sp1800sp.cmd 1999/09/01 sp1802en.cmd 2007/09/04 modified sr30.cmd 2007/09/13 new product sr61en.cmd 2007/09/04 modified ============================ IMPROVEMENTS / NEW FEATURES ============================ --------------------------------------------------------------- New setup file version list --------------------------------------------------------------- - added list of setup files and versions (date) in this EasySet readme file with indication of change status (see previous section) --------------------------------------------------------------- New product - CN3 --------------------------------------------------------------- - added new product --------------------------------------------------------------- New product - SR30 --------------------------------------------------------------- - added new product --------------------------------------------------------------- New bitfield selection windows --------------------------------------------------------------- - added new window type allowing selection of a combination of bitfield values (video start/stop conditions and snapshot start conditions in the "Imager settings" for the EX25 product) --------------------------------------------------------------- ISCP online help accessible from EasySet main window --------------------------------------------------------------- - added new button to Help toolbar in EasySet main window to display ISCP online help (previously only accessible from ISCP Terminal window) --------------------------------------------------------------- New online help button icons --------------------------------------------------------------- - modified EasySet and ISCP online help button icons in EasySet main window and ISCP Terminal window =============================================== PROBLEM CORRECTIONS =============================================== --------------------------------------------------------------- New product refresh problem --------------------------------------------------------------- - corrected new product refresh problem following selection of a new product in the "Select product" window (in some cases the new product was not displayed in the EasySet window after a change of product) Reminder: Double-clicking the new product icon in the "Select product" window closes the window and displays the new product (same as clicking the OK button). --------------------------------------------------------------- New product family names in "Select product" window --------------------------------------------------------------- - modified product family names in the "Select product" window: - "Handheld scanners" instead of "Hand-held scanners" - "Handheld computers" instead of "Terminals" --------------------------------------------------------------- Incomplete code labels in setup sheet --------------------------------------------------------------- - corrected problem of incomplete code descriptions in setup sheet (long labels of more than 100 characters were truncated) --------------------------------------------------------------- "Get data string" Close button label --------------------------------------------------------------- - corrected Close button label for "Get data string" function (available on right-click in commands window if a setup command is selected) --------------------------------------------------------------- Disconnect after "Connection lost" message (online setup) --------------------------------------------------------------- - modified behavior and message after "Connection lost" situation occurs - user can now choose to close the connection and COM port or leave it open (useful if product connection is only lost temporarily) --------------------------------------------------------------- Improved entry of numerical values in numerical "Compose" windows --------------------------------------------------------------- - modified input validation checking during entry of numerical values - it is no longer possible to enter spaces in number entry fields _______________________________________________________________ _______________________________________________________________ EasySet - Version 5.4.3.0 _______________________________________________________________ ===================== Plugin / DLL versions ===================== - ActiveSyncISCP.dll - 1.0.0.6 + RAPI_API.dll ActiveSync interface DLL + companion DLL - Interlink.exe - 0 2 4 1 _ 2 04 >>> new executable - ISCP_cmd_set.chm - 1.5 >>> new version ISCP online help file - IscpRsPlugin.dll - 1.0.3.4 old RS serial interface DLL - ISDC_Rs.dll - 1.1.0.2 new RS serial interface DLL - SF51.dll - 9.9.0.0 >>> new version Bluetooth interface DLL - SF51Upgrade.exe - 1.0.3.161 SF51 Firmware Upgrade Utility - Winflash.msi - 3.0.9.1 >>> new version WinFlash firmware download plugin ============================ IMPROVEMENTS / NEW FEATURES ============================ --------------------------------------------------------------- New product - EX25 --------------------------------------------------------------- - added new product --------------------------------------------------------------- EasySet PC screen size / resolution values --------------------------------------------------------------- - values now saved in "ScreenRes" section in "easyset.ini" file --------------------------------------------------------------- Support for multiple firmware upgrade tool versions (EA15 imager) --------------------------------------------------------------- Some products such as the EA15 imager use different firmware upgrade tools for different versions of the product. In this case, a list of choices is displayed when you select "Tools - Upgrade product firmware". If you do not know which tool to use, try each tool until you find the one which works with your product version. For the EA15 imager : - early versions use a dedicated Firmware Upgrade Tool ("Interlink.exe") - all other versions use the standard Firmware Upgrade Tool ("WinFlash.exe") --------------------------------------------------------------- "Interlink.exe" Firmware Upgrade Tool --------------------------------------------------------------- - included this tool for early versions of the EA15 imager (see previous note) --------------------------------------------------------------- New error codes for online communication --------------------------------------------------------------- - added support for two new error codes: 4 Allocation Error 12 Internal Error =============================================== PROBLEM CORRECTIONS =============================================== --------------------------------------------------------------- "Division by zero" problem at startup --------------------------------------------------------------- - corrected this problem encountered when using the EasySet PC with an external peripheral (overhead projector for example) Remark: Run EasySet at least once "standalone" before connecting to the external peripheral (overhead projector, ...). --------------------------------------------------------------- Bluetooth error logic correction --------------------------------------------------------------- - removed unnecessary processing after DLL error has been detected during online configuration (Bluetooth products) --------------------------------------------------------------- Online disconnect for certain error types --------------------------------------------------------------- - online disconnect already implemented for error 10 Connection Lost - added online disconnect for error 12 Internal Error - added online disconnect for unknown error codes --------------------------------------------------------------- Online refresh commands --------------------------------------------------------------- - added refresh of commands tree if "administrator reset factory defaults" command sent online to product (parameter in [ResetCommands] section of "easyset.ini" file) _______________________________________________________________ _______________________________________________________________ EasySet - Version 5.4.2.2 _______________________________________________________________ Note: Version 5.4.2.2 is incorrectly indicated as 4.5.2.2 on the desktop and in the Programs menu. To check the correct version number do one of the following: - run EasySet and open the Help - About EasySet window - right-click the "easyset.exe" file in the EasySet installation directory and choose "Properties" ===================== Plugin / DLL versions ===================== - ActiveSyncISCP.dll - 1.0.0.6 + RAPI_API.dll ActiveSync interface DLL + companion DLL - ISCP_cmd_set.chm - 1.0 ISCP online help file - IscpRsPlugin.dll - 1.0.3.4 old RS serial interface DLL - ISDC_Rs.dll - 1.1.0.2 new RS serial interface DLL - SF51.dll - 1.1.3.160 Bluetooth interface DLL - SF51Upgrade.exe - 1.0.3.161 SF51 Firmware Upgrade Utility - Winflash.msi - 3.0.8.8 WinFlash firmware download plugin ============================ IMPROVEMENTS / NEW FEATURES ============================ --------------------------------------------------------------- New ActiveSync DLL version + additional DLL : RAPI_API.dll --------------------------------------------------------------- - support for online setup of terminals (700C, CK30, . . .) from EasySet : - product setup can be modified from EasySet - EasySet displays current product settings like for other products Remark : This functionality requires : - Microsoft ActiveSync installed and running on the EasySet PC - "ActiveSyncISCP.dll" and "RAPI_API.dll" present in your EasySet directory - latest "easyset.ini" file with ActiveSync settings for the products concerned --------------------------------------------------------------- New WinFlash version 3.0.8.8 --------------------------------------------------------------- _______________________________________________________________ _______________________________________________________________ EasySet - Version 5.4.2.1 _______________________________________________________________ ===================== Plugin / DLL versions ===================== - ActiveSync interface DLL (ActiveSyncISCP.dll) 1.0.0.5 - Bluetooth interface DLL (SF51.dll) 1.1.3.160 - ISCP online help file (ISCP_cmd_set.chm) 1.0 - RS serial interface DLL (IscpRsPlugin.dll) 1.0.3.4 - RS serial interface DLL (ISDC_Rs.dll) 1.1.0.2 - SF51 Firmware Upgrade Utility (SF51Upgrade.exe) 1.0.3.161 - WinFlash firmware download plugin (winflash.msi) 3.0.8.7 ============================ IMPROVEMENTS / NEW FEATURES ============================ --------------------------------------------------------------- New ActiveSync DLL for online setup of terminals (700C, CK30, . . .) --------------------------------------------------------------- - added support for online setup of terminals (700C, CK30, . . .) from EasySet : - product setup can be modified from EasySet - EasySet displays current product settings like for other products Remark : This functionality requires : - Microsoft ActiveSync installed and running on the EasySet PC - "ActiveSyncISCP.dll" present in your EasySet directory - latest "easyset.ini" file with ActiveSync settings for the products concerned --------------------------------------------------------------- New ISCP DLL for serial communication (RS serial interface) --------------------------------------------------------------- - added new DLL "ISDC_Rs.dll" to replace "IscpRsPlugin.dll" --------------------------------------------------------------- New help button for ISCP commands in ISCP terminal window --------------------------------------------------------------- - added new Help button to toolbar in ISCP terminal window for information on ISCP commands (button only displayed if "ISCP_cmd_set.chm" file is present in EasySet directory) --------------------------------------------------------------- Extended barcode data format / --------------------------------------------------------------- / ISCP command types allow you to display extended barcode data information - all products except SF51 and SR61: the ISCP command now replaces the command (the ISCP command type values have been inverted for these products) - SF51 and SR61 products: no change, note that for these products does not process the data format the same way as for all other products Remark: The "Data transmission settings - ISCP - data format - packet" setup option must be activated if you want to use / to display extended barcode data information --------------------------------------------------------------- DLL version display in "About EasySet" window (online configuration) --------------------------------------------------------------- - DLL version field can now display more than one line and refreshes each time the "About EasySet" window is displayed Reminder: Current DLL version is displayed in the "About EasySet" window when online communication with the product has been established --------------------------------------------------------------- Negative values entry and display --------------------------------------------------------------- - some new functions require negative values - these values can be entered when applicable and are displayed during online product configuration =============================================== PROBLEM CORRECTIONS =============================================== --------------------------------------------------------------- Disappearing floating toolbar in ISCP terminal window --------------------------------------------------------------- - corrected disappearing floating toolbar problem: if floating toolbar is closed, closing and reopening the ISCP terminal window displays the toolbar again (previously the toolbar was "lost") --------------------------------------------------------------- EasySet crash if floating toolbar in ISCP terminal window when change product --------------------------------------------------------------- - corrected EasySet crash: EasySet no mopnger crashes if toolbar in ISCP terminal window is floating when a new product is selected --------------------------------------------------------------- Improved DLL error message logic (online configuration) --------------------------------------------------------------- - removed unnecessary processing after DLL error has been detected during online configuration _______________________________________________________________ _______________________________________________________________ EasySet - Version 5.4.2.0 _______________________________________________________________ ===================== Plugin / DLL versions ===================== - WinFlash firmware download plugin (winflash.exe) 3.0.8.5 - SF51 Firmware Upgrade Utility (SF51Upgrade.exe) 1.0.3.161 - RS serial interface DLL (IscpRsPlugin.dll) 1.0.3.4 - Bluetooth interface DLL (SF51.dll) 1.1.3.160 ============================ IMPROVEMENTS / NEW FEATURES ============================ --------------------------------------------------------------- New product - EA15 --------------------------------------------------------------- - added new product ________________________________________________________________ CODE DISPLAY IN SETUP SHEET ________________________________________________________________ --------------------------------------------------------------- Setup sheet page size --------------------------------------------------------------- - the on-screen page size of the setup sheet is approximately 100% A4 (default) or US letter, depending on current default printer setting --------------------------------------------------------------- Adjustable code width in non-concatenated mode --------------------------------------------------------------- - the code width selector in the toolbar is now available for non-concatenated codes in the setup sheet (previously only enabled for concatenated codes) --------------------------------------------------------------- Maximum code width value --------------------------------------------------------------- - the maximum code width value has been extended from 16 cm to 18 cm - the current selected code width is saved in the ".cfg" file if you save the current setup sheet config (File - Save / Save as), whether unconcatenated or concatenated - the width value is now at the beginning of the parameter list in the first line of the ".cfg" file but compatibility with previous ".cfg" files is maintained --------------------------------------------------------------- Wide codes split into subcodes (ISCP products only) --------------------------------------------------------------- - codes that are too wide for the page or for the selected code width are split into a number of subcodes - keep the product trigger pressed and read all the subcodes in any order (each code will click, the last code will give the setup beeps) - for Cut / Copy / Paste and Undo operations and "Send selected command" to product, related subcodes are handled like a single code (select one of the subcodes and perform the desired operation) - subcodes cannot be concatenated, but increasing the code width with the code width selector may restore the subcodes to a single code that can be concatenated --------------------------------------------------------------- REMARK : Reminder for advanced print options (File - Advanced print options) --------------------------------------------------------------- Advanced print options (module width and bar/space adjustment) are applied to printouts with a printer but are not visible on the screen due to screen resolution limitations. --------------------------------------------------------------- =============================================== PROBLEM CORRECTIONS =============================================== ________________________________________________________________ CODE DISPLAY IN SETUP SHEET ________________________________________________________________ --------------------------------------------------------------- EasySet crash if long code in concatenation --------------------------------------------------------------- - corrected crash problem if code width longer than current selected concatenation width (no response from EasySet) --------------------------------------------------------------- Horizontal page overflow of long codes --------------------------------------------------------------- - corrected horizontal overflow of page for long codes (codes that previously went off the page are now split into subcodes, see "Improvements / New features" section above) --------------------------------------------------------------- Bottom of page overflow --------------------------------------------------------------- - corrected vertical overflow of page display at bottom of page that could occur according to page content and screen resolution - concatenated code labels follow code onto next page if necessary (previously some labels could be displayed at the bottom of the page and the following labels on the next page with the code) --------------------------------------------------------------- Unnecessary empty new page --------------------------------------------------------------- - corrected unnecessary display of empty next page when last code is added at bottom of page --------------------------------------------------------------- Incorrect code width calculation --------------------------------------------------------------- - corrected code width calculation for concatenated codes (page width / code width selector) --------------------------------------------------------------- "Concatenate" button icon --------------------------------------------------------------- - corrected behavior of "Concatenate" toolbar button icon when switching between concatenated and non-concatenated mode from Edit menu (Edit - Concatenate) --------------------------------------------------------------- "Hide command names" and "Hide border" buttons --------------------------------------------------------------- - corrected non-display of "Hide command names" and "Hide border" toolbar buttons (in previous versions they were accidentally hidden) _______________________________________________________________ _______________________________________________________________ EasySet - Version 5.4.1.1 _______________________________________________________________ ===================== Plugin / DLL versions ===================== - WinFlash firmware download plugin (winflash.exe) 3.0.8.5 - SF51 Firmware Upgrade Utility (SF51Upgrade.exe) 1.0.3.161 - RS serial interface DLL (IscpRsPlugin.dll) 1.0.3.4 - Bluetooth interface DLL (SF51.dll) 1.1.3.160 =============================================== PROBLEM CORRECTIONS - Bluetooth products (SF51,SR61,...) =============================================== --------------------------------------------------------------- Error message with "Connect/Disconnect" button in ISCP terminal window --------------------------------------------------------------- - corrected behavior for Bluetooth products (no send of "silent mode off" at online activation, no send of "restart product" at online deactivation) --------------------------------------------------------------- Error message when quitting EasySet with a Bluetooth product connected online --------------------------------------------------------------- - corrected behavior when closing EasySet with Bluetooth product online (no send of "restart product" on closing) _______________________________________________________________ _______________________________________________________________ EasySet - Version 5.4.1.0 _______________________________________________________________ ===================== Plugin / DLL versions ===================== - WinFlash firmware download plugin (winflash.exe) 3.0.8.5 - SF51 Firmware Upgrade Utility (SF51Upgrade.exe) 1.0.3.161 - RS serial interface DLL (IscpRsPlugin.dll) 1.0.3.4 - Bluetooth interface DLL (SF51.dll) 1.1.3.160 ============================ IMPROVEMENTS / NEW FEATURES ============================ --------------------------------------------------------------- New product - EV12 --------------------------------------------------------------- - added new product --------------------------------------------------------------- New product - SR61 --------------------------------------------------------------- - added new product --------------------------------------------------------------- Commands window icons for ISCP products --------------------------------------------------------------- - added new icons to distinguish Control commands (cog icon) and Status Read commands ("i" icon for "information") from Setup Write commands (standard "document" icon) --------------------------------------------------------------- Commands window icon for "dummy" command --------------------------------------------------------------- - added new icon for "dummy" command ("EasySet online setup" in the "Using EasySet" section) --------------------------------------------------------------- Commands window popup to get command datastring (ISCP and non-ISCP commands) --------------------------------------------------------------- - added new popup menu item (right-click on command) to get ISCP data string : - ISCP data strings displayed without "" but with spaces and range/type info if applicable - non-ISCP command data strings - data string window and edit field resizeable --------------------------------------------------------------- Extended COM port selection for non-ISCP products --------------------------------------------------------------- - added new COM selector (COM ports 1 to 20) for non-ISCP products when connecting for online setup --------------------------------------------------------------- ISCP Terminal window --------------------------------------------------------------- - modified behavior of "Convert ISCP ASCII strings to Hex" toolbar button and renamed to "Display ISCP commands as Hex": when pressed, all subsequent ISCP commands are displayed as hex values only (including cleartext labels for ISCP commands / return values and ASCII strings) - moved "Clear window" toolbutton to beginning of toolbar --------------------------------------------------------------- Data editing function - ISCP products - Action list window --------------------------------------------------------------- - added hints for special pushbuttons - added "Delete all characters from character N" (beginning of data) / "Delete last N characters" (end of data) function (select "0" in the "Delete" number of characters selector) - added indication that an action has been initiated ("Add to Action list" button highlighted and bold red button caption) as a reminder that new action must be added to Action list before clicking OK - added indication that a change of trackbar resolution has been initiated ("Resolution" button highlighted and bold red button caption) as a reminder that the resolution change must be confirmed (click "Resolution button or hit ) - added use of key to confirm trackbar resolution change following entry of new value or using updown spinner button (previously hitting closed the window) - added detection online to check if the current scenario has been activated ("Activate scenario ?" message is now displayed, if the user replies "Yes" the scenario is activated when the Action list window is closed with the "OK" button) - added detection online of invalid editing actions if a fixed input length has been set for the current scenario (a message is displayed but the action is authorized) --------------------------------------------------------------- "Incorrect command" message (ISCP products online) --------------------------------------------------------------- - modified to "unsupported command" if command not supported by product ============================ PROBLEM CORRECTIONS - General ============================ --------------------------------------------------------------- Commands window display --------------------------------------------------------------- - corrected display of "help" info in the information window for last command in the commands window (previously not displayed) --------------------------------------------------------------- Setup button in ISCP terminal window --------------------------------------------------------------- - removed (did not operate correctly and not necessary, use "Connect" buttton instead) --------------------------------------------------------------- Data editing function - ISCP products - Action list window --------------------------------------------------------------- - corrected Action list reset operation (no commands in Action list resets Action list for current scenario) - corrected behavior of key in "define number of characters" entry field (previously hitting closed the window) --------------------------------------------------------------- Improved handling of ISCP online error messages --------------------------------------------------------------- - now only one message when previously there were two or more in some cases ("Connection lost") - error message if EasySet tries to send an unknown frame type (UFT) - error message if product returns "Group unknown" (), "Identifier unknown" (), "Invalid parameter" () or unknown value --------------------------------------------------------------- Unwanted commands for Bluetooth products (SF51,SR61,...) --------------------------------------------------------------- - corrected behavior of EasySet (display of "Identifier unknown" error messages) during : - online activation : ("silent mode off" command not supported by products) - online deactivation : ("restart product" command not supported by products) =============================================== PROBLEM CORRECTIONS - EasySet online for non-ISCP products =============================================== --------------------------------------------------------------- RS-232 online connection via USB port replicator hub (EasySet online for non-ISCP products) --------------------------------------------------------------- - corrected online connection problem for PCs and laptops via USB port replicator hub (previously not always possible for PCs or laptops with no integrated serial port) --------------------------------------------------------------- Close Com port (EasySet online for non-ISCP products) --------------------------------------------------------------- - corrected closing of Com port if online connection failure (previously Com port possibly left open) --------------------------------------------------------------- Product restart on change of product (EasySet online for non-ISCP products) --------------------------------------------------------------- - corrected restart of product at product change to quit EasySet online mode (product previously remained in EasySet online mode, now on/off command sent to product) --------------------------------------------------------------- Product restart on EasySet shutdown (EasySet online for non-ISCP products) --------------------------------------------------------------- - corrected restart of product to quit EasySet online mode when quitting EasySet (product previously remained in EasySet online mode, now on/off command sent to product) --------------------------------------------------------------- Auto-reconnect on EasySet startup (EasySet online for non-ISCP products) --------------------------------------------------------------- - corrected auto-reconnect of product at startup of EasySet if product was used online in previous EasySet session (previously auto-reconnect did not occur) Remark: Auto-reconnect at EasySet startup is not implemented for ISCP products --------------------------------------------------------------- Occasional error message for "Send all commands (EasySet online for non-ISCP products) --------------------------------------------------------------- - corrected incorrect display of error message if a command name includes "<" character during "Send all commands to product" action (previously error message was displayed) _______________________________________________________________ _______________________________________________________________ EasySet - Version 5.4.0.0 _______________________________________________________________ ===================== Plugin / DLL versions ===================== - WinFlash firmware download plugin (winflash.exe) 3.0.8.5 - SF51 Firmware Upgrade Utility (SF51Upgrade.exe) 1.0.3.122 - RS serial interface DLL (IscpRsPlugin.dll) 1.0.3.0 - SF51 Bluetooth interface DLL (SF51.dll) 1.0.2.5 =========================== IMPROVEMENTS / NEW FEATURES =========================== --------------------------------------------------------------- Product selection --------------------------------------------------------------- - redesigned to display products by type of product (product families or categories) - customizable in easyset.ini file: - creation of new categories possible ("[ProductFamilies]" section in ini file) - assignment of products to categories using "family" parameter in product line in ini file - vastly extended capacity for number of products supported - modified display of product captions in product selector (now uppercase and no longer double name for certain products) - modified display of product image in main window (product caption now displayed next to image) --------------------------------------------------------------- Data editing function - ISCP products --------------------------------------------------------------- - added support for data editing with ISCP (in "Data transmission settings" section) --------------------------------------------------------------- ISCP --------------------------------------------------------------- - added support for BarcodeDataEx ISCP operation - added support for frames --------------------------------------------------------------- Numerical value dialog boxes --------------------------------------------------------------- - display product value setting when online with ISCP products - select value in data entry field on open of dialog box --------------------------------------------------------------- Terminal selector --------------------------------------------------------------- - included new set of ".cnd" files for terminal selector database =================== PROBLEM CORRECTIONS =================== --------------------------------------------------------------- Product selection --------------------------------------------------------------- - corrected behavior during selection of product with incorrect setup file (bad checksum for example) : "Select product" button at product image location now remains available, comments window cleared --------------------------------------------------------------- ENQ/ACK/NAK --------------------------------------------------------------- - corrected display of data entry box (character selection grid was truncated) --------------------------------------------------------------- Special ASCII characters --------------------------------------------------------------- - modified display of ASCII characters to , to , to in dialog box displays (Preamble, Postamble, . . .) and dropdown lists to use same convention in all cases --------------------------------------------------------------- Non-ISCP data editing function --------------------------------------------------------------- - corrected possible erratic display of "Input type" dropdown list (list didn't stay open if it "hit" the top of the screen ) --------------------------------------------------------------- Beeps note (tone frequency) --------------------------------------------------------------- - corrected display for frequency values in commands window during online setup --------------------------------------------------------------- ISCP Terminal window --------------------------------------------------------------- - corrected end-of-line display when reading bar codes --------------------------------------------------------------- Improved handling of ISCP error messages --------------------------------------------------------------- - now only one message when previously there were two in some cases _______________________________________________________________ _______________________________________________________________ EasySet - Version 5.3.0.0 _______________________________________________________________ ===================== Plugin / DLL versions ===================== - WinFlash firmware download plugin (winflash.exe) 3.0.8.3 - SF51 Firmware Upgrade Utility (SF51Upgrade.exe) 1.0.3.122 - RS serial interface DLL (IscpRsPlugin.dll) 1.0.2.7 - SF51 Bluetooth interface DLL (SF51.dll) 1.0.2.5 =========================== IMPROVEMENTS / NEW FEATURES =========================== --------------------------------------------------------------- EasySet window --------------------------------------------------------------- - redesigned to allow resizing of panes - added new control panel at top of commands window (contains product selector icon, Send to sheet / Send to product checkboxes, Send button) - added movable toolbars and redrew some button icons - optimized commands window scrolling when in online setup mode (new treeview component, Setup Read only performed once for commands) REMARK: Disconnecting/reconnecting the product and changing setup by optical reading of configuration codes are not detected in this version of EasySet - use the new "Refresh display" option (see next line) to take thes actions into account - added "Refresh display" menu option and toolbar button - added contextual popup menu in commands window ("Collapse all", "Collapse branch", "Refresh display", "Send selected command to product" options) - added "Search" menu option and toolbar button (hint: double-click closes Search panel) --------------------------------------------------------------- ISCP Terminal window --------------------------------------------------------------- - redesigned to widen display panel - made window resizable - improved refresh performance when changing values in ISCP datastring field - improved display of Setup Read function - GID and FID now displayed (with length info if applicable) with parameter value - enabled use of "delete" button in ISCP command "Send" entry box - Carriage Return / Enter in ISCP command "Send" entry box sends command to product --------------------------------------------------------------- SF51 Firmware Upgrade Utility --------------------------------------------------------------- - added, can be launched from "Tools- Upgrade product firmware" menu option (SF51Upgrade.exe must be present in EasySet directory for this) or can be run standalone outside of EasySet --------------------------------------------------------------- EV15 scan engine - new "Filter select" window --------------------------------------------------------------- - added new "Filter selection" windows for the EV15 scan engine 1D and stacked filters ("read optimization - filter sequence" section in commands window) =================== PROBLEM CORRECTIONS =================== --------------------------------------------------------------- Printer management --------------------------------------------------------------- - corrected printer management at startup or request for "Print" / "Advanced print options" if no printer available --------------------------------------------------------------- ISCP Terminal window --------------------------------------------------------------- - corrected ISCP command database creation (some commands present in the "iscp.iscp" file were not added to the database) _______________________________________________________________ _______________________________________________________________ EasySet System Version 5.2.0.0 _______________________________________________________________ =========================== IMPROVEMENTS / NEW FEATURES =========================== _______________________________________________________________ GENERAL _______________________________________________________________ --------------------------------------------------------------- Firmware download --------------------------------------------------------------- - includes WinFlash 3.0.8.2 firmware download plugin --------------------------------------------------------------- RS serial interface DLL --------------------------------------------------------------- - includes RS serial interface DLL 1.0.2.0 --------------------------------------------------------------- SF51 Bluetooth interface DLL --------------------------------------------------------------- - includes SF51 Bluetooth interface DLL 1.0.2.5 --------------------------------------------------------------- EV15 scan engine --------------------------------------------------------------- - added support for the EV15 scan engine --------------------------------------------------------------- "Send to sheet" / "Send to product" checkboxes --------------------------------------------------------------- - added "Send to sheet" checkbox (default for offline setup) - "Send to product" checkbox is default for online setup - allows independent selection of command destination and avoids "Command already exists" messages when working online --------------------------------------------------------------- Step-by-step mode removed --------------------------------------------------------------- - removed Step-by-step mode to simplify interface --------------------------------------------------------------- ISCP Terminal window --------------------------------------------------------------- Added "Convert ISCP ASCII strings to Hex" button to toolbar - when pressed, subsequent strings received in ISCP packets are displayed as hex values instead of ASCII - useful for certain setup read or status requests (filter lists, hex ID masks, ...) Added cleartext labels for ISCP command return codes ( for "Done" etc.) =================== PROBLEM CORRECTIONS =================== --------------------------------------------------------------- Problems on close of EasySet --------------------------------------------------------------- - corrected: removed unwanted error messages if product disconnected on close of EasySet - corrected: reenabled hardware reset to quit EasySet online mode for non-ISCP products on close of EasySet --------------------------------------------------------------- Problem on reception of unexpected data in ISCP Terminal window --------------------------------------------------------------- - corrected: improved error handling / error messages --------------------------------------------------------------- Potential problem creating ISCP Terminal window database --------------------------------------------------------------- - corrected: potential missing lines when creating database --------------------------------------------------------------- Problem with hex entry window (e.g. Bluetooth - compose BT address) --------------------------------------------------------------- - corrected: no longer possible to enter more than two characters in the last hex entry box _______________________________________________________________ _______________________________________________________________ EasySet System Version 5.1.0.0 _______________________________________________________________ ================================================= PROBLEM CORRECTIONS / IMPROVEMENTS / NEW FEATURES ================================================= _______________________________________________________________ GENERAL _______________________________________________________________ --------------------------------------------------------------- Firmware download --------------------------------------------------------------- - includes WinFlash 3.0.8.0 firmware download plugin --------------------------------------------------------------- ASCII string entry window --------------------------------------------------------------- - corrected truncated window display problem --------------------------------------------------------------- Numerical value selectors --------------------------------------------------------------- - extended max range from possible 15-bit (decimal 32000) to 63-bit values (but spinner button not available for high-end values) ________________________________________________________________ INTERMEC SCANNER CONTROL PROTOCOL (ISCP) ________________________________________________________________ --------------------------------------------------------------- ISCP - product connection problem --------------------------------------------------------------- - corrected problem when connecting ISCP product for online communication (E1022 for example) - in some cases EasySet entered a blocking error state when setup commands visible in commands window during connection --------------------------------------------------------------- ISCP - new hex value entry window --------------------------------------------------------------- - added window to enter hex strings if required --------------------------------------------------------------- ISCP - new filter selection window --------------------------------------------------------------- - added window to select optimization filters (E1022) --------------------------------------------------------------- ISCP - ASCII string entry window --------------------------------------------------------------- - added capability to enter hex values for characters higher than decimal ASCII value 127 --------------------------------------------------------------- ISCP - Terminal window --------------------------------------------------------------- - corrected display of high range values in ISCP workshop parameters (ISCP Terminal window) - added capability to choose COM ports 1 to 20 (not just 1 and 2) ________________________________________________________________ DLLs FOR ISCP COMMUNICATION BETWEEN CERTAIN PRODUCTS AND EASYSET ________________________________________________________________ --------------------------------------------------------------- DLL - Bluetooth communication (SF51) --------------------------------------------------------------- - added SF51.dll for ISCP communication with SF51 (Bluetooth wireless communication) --------------------------------------------------------------- DLL - RS communication (E1022) --------------------------------------------------------------- - added IscpRsPlugin.dll for ISCP communication with E1022 (RS communication through serial port) --------------------------------------------------------------- DLL - Modified Communication menu options for products with DLL communication --------------------------------------------------------------- - single DLL: - "Setup" menu option renamed "Connect" or "Disconnect" depending on whether product connected and online - selecting "Connect" displays "Connection Parameters" selection window if applicable (click OK to connect the product) - ISCP Terminal window only displayed if requested - multiple DLLs: - "Setup" menu option renamed "Select communication interface" if more than one DLL declared in the product's parameters in "easyset.ini" - selecting "Select communication interface" displays "Communication Interface" selection window (click OK to connect the product) - ISCP Terminal window only displayed if requested --------------------------------------------------------------- DLL - Version display --------------------------------------------------------------- - DLL version displayed in "About EasySet" window while product connected _______________________________________________________________ _______________________________________________________________ EasySet - Version 4.9.2.0 _______________________________________________________________ --------------------------------------------------------------- 1. INSTALLATION --------------------------------------------------------------- - modified installation properties to improve EasySet installation management : - install to same EasySet directory as previous version uninstalls previous version - cleaner uninstall of new version (.exe and .hlp files are uninstalled correctly as they no longer have the "shared" registry attribute and are not "refcounted") - possibility to keep previous version if required IMPORTANT : If you want to keep your previous version of EasySet as well as the new version, rename your existing EasySet directory before you install EasySet 4.9.2.0. - the following products are not included in this install package : MaxiScan 1000 MaxiScan 2100 MaxiScan 2200 MaxiScan 3010 MaxiScan 3100 MaxiScan 3300 - if your product is in this list, install EasySet 4.9.2.0. and copy the corresponding product files to your newly installed EasySet directory (the required product files are available on the Intermec downloads website) --------------------------------------------------------------- 2. NEW FEATURES --------------------------------------------------------------- Firmware download --------------------------------------------------------------- - includes WinFlash 3.0.7.5 firmware download plugin (already included with version 4.9.1.0) _______________________________________________________________ _______________________________________________________________ EasySet - Version 4.9.1.0 _______________________________________________________________ --------------------------------------------------------------- 1. INSTALLATION --------------------------------------------------------------- - removed following products to make room for new products : MaxiScan 1000 MaxiScan 2100 MaxiScan 2200 MaxiScan 3010 MaxiScan 3100 MaxiScan 3300 - if your product is in this list, do not uninstall or overwrite your current version of EasySet - removed E1022 scan engine with mixed ISCP / non-ISCP functionality, online setup with ISCP, offline setup with non-ISCP configuration code labels (setup file available separately) - added E1022 scan engine with full ISCP functionality, online setup with ISCP, offline setup with ISCP configuration code labels --------------------------------------------------------------- 2. NEW FEATURES --------------------------------------------------------------- Online setup and control using Intermec Scanner Control Protocol (ISCP) - E1022 scan engine --------------------------------------------------------------- - product online setup and control from new ISCP Terminal window (select Communication - Setup to enter online setup mode) - product online setup from EasySet main window for products using ISCP - current product settings displayed in EasySet commands window (ISCP products only) --------------------------------------------------------------- 3. PROBLEM CORRECTIONS / IMPROVEMENTS --------------------------------------------------------------- Product selector --------------------------------------------------------------- - removed end-of-life products to make room for new products (if your product is not shown in the product selector window, install the previous version of EasySet) --------------------------------------------------------------- File - Open / Save / Save as --------------------------------------------------------------- - dialog boxes now open in current EasySet directory --------------------------------------------------------------- Intermec web links --------------------------------------------------------------- - modified web links in EasySet main window and Terminal Selector window to point to www.intermec.com --------------------------------------------------------------- WinFlash new version detection --------------------------------------------------------------- - Open dialog box opens at easyset_directory/WinFlash if a more recent version of WinFlash is available following new installation --------------------------------------------------------------- Data editing (product-specific) --------------------------------------------------------------- - added to "Input type" list : Codablock 256, Code 16K, Code 39 CPI, Code 49, DataMatrix, MaxiCode, MicroPDF417, QR Code, RSS 14 / Expanded / Limited - removed yellow color for enabled controls, modified "enabled / disabled" control color display --------------------------------------------------------------- Scale solicitation (product-specific) --------------------------------------------------------------- - added to "Input type" list : Codablock 256, Code 16K, Code 39 CPI, Code 49, MicroPDF417, RSS 14 / Expanded / Limited _______________________________________________________________ _______________________________________________________________ EasySet - Version 4.6.0.0 _______________________________________________________________ --------------------------------------------------------------- 1. INSTALLATION --------------------------------------------------------------- Installation --------------------------------------------------------------- - EasySet and WinFlash (Intermec firmware download wizard) can be installed and run independently - WinFlash can be installed / run from inside EasySet ("Tools - Upgrade product firmware" menu option) - download EasySet and WinFlash from: http://datacapture.intermec.com/isd/datacapture/datacapturesoftware.nsf in the "Software" section - EasySet (EasySet + Windows Installers + WinFlash) in the "Firmware" section : - WinFlash - both products use Windows Installer for install/uninstall - the setup.exe package for EasySet will install the MSI 2.0 Windows Installer if required (the system may need to be restarted for the Windows Installer to be updated) - for Windows NT4 platforms, MSI 2.0 requires SP6 (SP3 requires MSI 1.2) - OS-specific versions of the Windows Installer are available from http://www.microsoft.com/downloads --------------------------------------------------------------- Uninstall issues --------------------------------------------------------------- 1 : Uninstall does not remove new files added after the initial installation (EasySet ".cfg" files, terminal selector database files, "easyset.gid" Help file, user-created files, ...) Workaround : These files and the EasySet directory must be removed manually if you wish to uninstall completely --------------------------------------------------------------- 2 : In addition to the above files, uninstall of EasySet may not remove the following files (incorrectly installed as shared files) : - easyset.exe - easyset.hlp - editing4.exe Workaround: Ask your Systems Engineer to remove the references to these files in the Windows registry under: [HKEY_LOCAL_MACHINE]\SOFTWARE\Microsoft\Windows\Current Version\SharedDLLs\[INSTALLDIR]\file_names In this case you may also have to manually remove the EasySet shortcuts (Start menu, desktop). --------------------------------------------------------------- Installation cleanup --------------------------------------------------------------- - installation package cleans up unnecessary registry entries from version 4.3.0.0 (HKCU) and includes new registry entries (HKLM) - corrected possible problem when launching EasySet at end of installation process --------------------------------------------------------------- 2. PROBLEM CORRECTIONS / IMPROVEMENTS --------------------------------------------------------------- "About EasySet" window --------------------------------------------------------------- - new logo and design - "EasySet System" name changed to just "EasySet" (registered trademark) - EasySet directory pathname can be displayed/selected even if it "goes off the page" --------------------------------------------------------------- product images in "Setup" and "Terminal selector" windows --------------------------------------------------------------- - improved display of product image --------------------------------------------------------------- setup command selection --------------------------------------------------------------- - improved management of setup command selection in commands window and setup sheet (now clearer which command is selected for online setup for example) - improved management of menu options / toolbar buttons with regard to command selection context in commands window and setup sheet --------------------------------------------------------------- setup sheet display --------------------------------------------------------------- - removed page number hint from setup sheet - removed line info in status bar with regard to command selection in setup sheet --------------------------------------------------------------- Edit - Cut --------------------------------------------------------------- - corrected behavior (removed confirmation request) --------------------------------------------------------------- File - Save / Save as --------------------------------------------------------------- - corrected behavior of Save and improved Save / Save as logic --------------------------------------------------------------- "Export to Word" --------------------------------------------------------------- - added export of new configuration bar codes for ISCP to "Export to Word" function --------------------------------------------------------------- Data editing (various products) --------------------------------------------------------------- - corrected "Access violation" problem when empty value (= "all input types") chosen in Input type dropdown lists --------------------------------------------------------------- Scale solicitation (MicroBar 9730, ScanPlus 1802) --------------------------------------------------------------- - corrected "Access violation" problem when empty value (= "all input types") chosen in Input type dropdown lists --------------------------------------------------------------- Internet web links --------------------------------------------------------------- - "Get latest version of EasySet" link (EasySet main window) now goes direct to "EasySet software" section of Data Capture web site - "Get latest firmware / Terminal Selector files" link (terminal selector window) now goes direct to "Product firmware" section of Data Capture web site --------------------------------------------------------------- 3. NEW FEATURES --------------------------------------------------------------- New config codes for ISCP --------------------------------------------------------------- - new configuration bar codes for ISCP (Intermec Scanner Control Protocol) products that support them - new codes can be recognized by "\60" at beginning of code instead of at end of code - added automatic support (product-specific) for all possible setup configurations (.cmd files) : - non-ISCP only : offline setup (setup sheet) + online setup (through serial port) - ISCP only : offline setup + online setup (online setup not yet implemented) - non-ISCP + ISCP : offline setup non-ISCP + online setup ISCP (online setup not yet implemented) --------------------------------------------------------------- Firmware download --------------------------------------------------------------- - includes WinFlash 3.0.7.0 firmware download plugin - WinFlash 3.0.7.0 now includes new "Help" download procedure --------------------------------------------------------------- Readme in Help menu --------------------------------------------------------------- - this "EasySet_readme.txt" file can be displayed from the EasySet Help menu --------------------------------------------------------------- Language versions --------------------------------------------------------------- - updated menus for different languages supported - EasySet now checks version of translated command file (date on first line of file, visible when mouse pointer is positioned over product image in EasySet) against English version and displays "English version more recent" message only if necessary _______________________________________________________________ _______________________________________________________________ EasySet System Version 4.3.0.0 _______________________________________________________________ --------------------------------------------------------------- 1. INSTALLATION --------------------------------------------------------------- - uses Windows Installer for install/uninstall - the setup.exe package will install MSI 2.0 (Windows Installer) if not installed or a more recent version needs to be installed (the system may need to be restarted for Windows Installer to be updated) - for Windows NT4 platforms: MSI 2.0 requires SP6, MSI 1.2 requires SP3 - OS-specific versions of the Windows Installer are available from http://www.microsoft.com/downloads --------------------------------------------------------------- 2. PROBLEM CORRECTIONS / IMPROVEMENTS --------------------------------------------------------------- Startup / printer driver issues with Windows 2000 --------------------------------------------------------------- - corrected slow EasySet startup that can occur with Windows 2000 (this problem is related to some printer drivers that are long to respond under Windows 2000 - if the "Print" and "Advanced Print Options" windows cause errors or unacceptable performance, try using another printer driver) - change of printer in "Advanced Print Options" window now via standard Windows printer setup dialog box --------------------------------------------------------------- Concatenated codes printout --------------------------------------------------------------- - corrected concatenated codes printout problem (version 4.2.0.0) --------------------------------------------------------------- "List index out of bounds" problem --------------------------------------------------------------- - corrected "List index out of bounds" problem at startup if unknown product name in ini file --------------------------------------------------------------- 3. NEW FEATURES --------------------------------------------------------------- Firmware download --------------------------------------------------------------- - integrated WinFlash 3.0.2.0 (new Intermec Firmware Download Wizard) - WinFlash version check "current installed version" vs "latest version number indicated in easyset.ini file" to ensure latest version is used --------------------------------------------------------------- Setup file / firmware version compatibillity --------------------------------------------------------------- - added display of latest firmware version supported by setup file (move mouse pointer over product icon to display setup file info) --------------------------------------------------------------- "Product - Select..." window --------------------------------------------------------------- - double-click on product icon closes window and applies selection (same as click on OK) --------------------------------------------------------------- "Compose character string" windows (preamble, postamble, ...) --------------------------------------------------------------- - modified control of supported characters (controlled from 1st line of product setup files) --------------------------------------------------------------- "Compose numerical values" windows (barcode length, ...) --------------------------------------------------------------- - modified barcode length "compose 1 or 2 or 3 fixed lengths" dialog box (removed erroneous label "If the 3 fixed lengths are 0, variable length is selected" and defined range of min/max values supported by product) - modified "compose [single_value]" dialog box (barcode length "compose minimum length" and other "compose" functions) in line with changes to "compose 1 or 2 or 3 fixed lengths" dialog box --------------------------------------------------------------- Data editing (various products) --------------------------------------------------------------- - "Input type" dropdown lists now show all symbologies/input types supported without need to scroll (reminder: RS-232 is often the correct input type selection for MicroBar ports 4 and 5) --------------------------------------------------------------- Scale solicitation (MicroBar 9730, ScanPlus 1802) --------------------------------------------------------------- - added input type information for "Input port" selection in "Scale solicitation" window - "Input type" dropdown list now shows all symbologies/input types supported without need to scroll (reminder: RS-232 is often the correct input type selection for MicroBar ports 4 and 5) --------------------------------------------------------------- Online setup --------------------------------------------------------------- - added possibility to inhibit online setup by including "offline" flag in ini file _______________________________________________________________ _______________________________________________________________ EasySet System Version 4.2 (Build 0.0) _______________________________________________________________ --------------------------------------------------------------- File menu --------------------------------------------------------------- - added "Advanced print options" menu option - wider codes (larger X-dimension) are more reader-tolerant - bar reduction/space increase reduces reading problems due to ink spread Remarks: - do not change the default settings if you can read your printouts with no problems !!! - configuration codes are now printed with greater precision and take into account individual printer driver characteristics --------------------------------------------------------------- Ini file --------------------------------------------------------------- - corrected "Range check error" bug if "easyset.ini" file incomplete (e.g. new product added and not included in ini file) _______________________________________________________________ _______________________________________________________________ EasySet System Version 4.1 (Build 0.1) _______________________________________________________________ --------------------------------------------------------------- Main window --------------------------------------------------------------- - EasySet no longer opens by default in Step-by-step mode - added link to Data Capture web site to get latest EasySet version (link can be customized in easyset.ini file, hint over link indicates URL) - corrected setup sheet title display (break in page margin) when fullscreen or resized after reducing - added text "Search box (select a term)" in search field at startup - improved toolbar button display - changed product icon to support all screen resolutions - modified display time of setup file version info hint (longer display when mouse pointer over product icon) --------------------------------------------------------------- File menu --------------------------------------------------------------- File - Open - modified file filter text of "File-Open/Save/Save As" dialog boxes to "EasySet setup sheet (*.cfg)" (was "Intermec product setup file (*.cfg)") - corrected "Setup file not found" problem if .cfg file not saved in EasySet directory File - Save as - modified behavior (".cfg" extension provided by default, setup sheet title proposed as default filename) File - Save - modified behavior (confirmation requested) File - Export to Word 97 - new function (+ new toolbar button) --------------------------------------------------------------- Edit menu --------------------------------------------------------------- Edit - Title - added "real" product name as default setup sheet title --------------------------------------------------------------- Product menu --------------------------------------------------------------- Product - Select - changed product bitmaps to support all screen resolutions - added "real" product names in hints - modified hint display times (quicker product name hint display) - current product switched off/on to quit EasySet online setup mode and revert to actual application settings + close COM port when new product selected in product selector - corrected display problem if try to change product and product setup file not available (in previous versions, the commands window was not updated but the product image changed to the "new" unavailable product) - added message informing that English version of setup file may be more recent than setup file in other language (if applicable) Product - Get firmware version - new function (enabled when product connected in EasySet online setup mode) --------------------------------------------------------------- Communication menu --------------------------------------------------------------- Communication - Setup - added "real" product name in product icon hint - modified number of stop bits for all products (was 1, now 2) in online setup parameters - added baud rate 57600 to Communication - Setup function (new products) - autodetect function (synchronization with product for online setup with EasySet) added for certain recent products (Sabre 1551, Sabre 1553, Sabre 1555, ...) Communication - Send selected command - corrected minor "send command to product" button activation problem Communication - Terminal - corrected "Get firmware version" option in "Communication - Terminal" window (didn't work for more recent products) --------------------------------------------------------------- Tools menu --------------------------------------------------------------- Tools - Upgrade product firmware - runs the Intermec Firmware Download Wizard ("download" subdirectory must be present in EasySet directory) Tools - Print test sheet - opens sheet of test codes ("testcode.pdf" file must be present in EasySet directory and Adobe Acrobat must be installed on PC) --------------------------------------------------------------- Help menu --------------------------------------------------------------- Help - Contents - improved online help Help - EasySet presentation - runs EasySet multimedia presentation (requires "Intermec products" cd-rom to run) - may not run correctly on Windows NT/2000 Help - About EasySet System - current EasySet directory path displayed in dialog box --------------------------------------------------------------- Terminal selector --------------------------------------------------------------- - corrected "Select product model" selection box if displayed (was resizeable) - added new separate field for cable firmware (only works with latest .cnd files, but terminal selector still compatible with old .cnd files) - added product icon with product name hint - added product name to product firmware field label - added link to Data Capture web site to get latest firmware/terminal selector file versions (link can be customized in easyset.ini file, hint over link indicates URL) --------------------------------------------------------------- Preamble / postamble --------------------------------------------------------------- - modified coding of character (more recent products only): always doubled in the datastring if is the first character in the preamble / postamble --------------------------------------------------------------- Data editing --------------------------------------------------------------- - added for Sabre 1551, Sabre 1553 (already present for MicroBar 9730 / 9735) - corrected / wildcards feature - added Help button (screencam demo) to editing window if screencam executable file available in EasySet directory - added Codablock A/F and PDF417 to symbology filters --------------------------------------------------------------- Scale solicitation (MicroBar 9730 / 9735) --------------------------------------------------------------- - corrected / wildcards feature (now works correctly) --------------------------------------------------------------- Online setup --------------------------------------------------------------- - switch product off/on to quit EasySet online setup mode and revert to actual application settings when EasySet is closed (certain more recent products) - autodetect for online setup attempted at beginning of new EasySet session if online setup performed in previous session (certain more recent products) - modified "COM port not available" routine to prevent lockup of EasySet when COM port in use with another application --------------------------------------------------------------- Sabre 1552 --------------------------------------------------------------- - run Visual Menu (separate software) when Sabre 1552 is selected in product selector (EasySet stays open, the currently selected product remains selected, COM port is closed if it was open) --------------------------------------------------------------- ScanImage 1470/1471 --------------------------------------------------------------- - run Visual Menu (separate software) when ScanImage 1470/1471 is selected in product selector (EasySet stays open, the currently selected product remains selected, COM port is closed if it was open) --------------------------------------------------------------- Sabre 1555 --------------------------------------------------------------- RFID tag functions: - Tag Read - Tag Write - Tag Filter - Tag/Mask Activate _______________________________________________________________ _______________________________________________________________ EasySet System Version 4.0 (build 1.1) - Update Patch _______________________________________________________________ --------------------------------------------------------------- "About EasySet System" window --------------------------------------------------------------- - changed copyright date from "1999" to "2000" --------------------------------------------------------------- Setup sheet --------------------------------------------------------------- - changed default title from "No name" to current product name - changed copyright date from "1999" to "2000" --------------------------------------------------------------- Open dialog box --------------------------------------------------------------- - corrected file type filter text (was "UBI reader", now "Intermec product") --------------------------------------------------------------- Commands window --------------------------------------------------------------- - optimized tree-view display --------------------------------------------------------------- Terminal selector --------------------------------------------------------------- - optimized (only opened when used) - improved security / reliability (BDE aliases created dynamically for the session, database files must be in current EasySet directory) - "Select product model" selection box displayed if different databases required for different models in selected product range (example: ScanPlus 1800 SR/ST, VT, PDF) - ONLY WORKS IF FIRST LINE OF ".cmd" FILE CONTAINS ".cnd:" FIELD AND EASYSET DIRECTORY CONTAINS CORRESPONDING ".cnd" FILES ! --------------------------------------------------------------- Preamble / postamble, custom symbology identifier (all products) --------------------------------------------------------------- - character '`' now available --------------------------------------------------------------- Data editing, Keyboard remapping, Scale solicitation (MicroBar 9730 / 9735) --------------------------------------------------------------- - character '`' now available --------------------------------------------------------------- Product selector --------------------------------------------------------------- - modified product images for MaxiScan 2200 and 3300 _______________________________________________________________ _______________________________________________________________ EasySet System Version 4.0 (build 0.0) _______________________________________________________________ --------------------------------------------------------------- Interface --------------------------------------------------------------- - "Reader" menu renamed "Product" - "Tools" menu renamed "Communication" - menu options "Initialize with - Selected command / All commands" and "Configure communication PC/Reader" moved from "Product" menu to "Communication" menu and renamed "Send selected command", "Send all commands", "Setup" --------------------------------------------------------------- Communication / online setup --------------------------------------------------------------- - modified dialog box used to set up serial communication between PC and product via RS-232 cable ("Setup" option in "Communication" menu) - also available from product selector dialog box - no longer necessary to read "start EasySet online setup" code to perform online setup with latest versions of MicroBar 9730 and MicroBar 9735 (ScanPlus 1802) (automatic connection using "Setup" in "Communication" menu) - modified "Terminal" window display (button display depends on selected product) - "Terminal" window stays open if online setup parameters are modified --------------------------------------------------------------- Product selector --------------------------------------------------------------- - modified dialog box used to select products ("Select" option in "Product" menu) - includes following options: - "online setup" - "select language" - "display automatically at startup" (default, can be deactivated) - "step-by-step mode" (default, can be deactivated) - replaced product selector "hand" and "product" icons in main window by new "product" button --------------------------------------------------------------- "Options - Language" --------------------------------------------------------------- - modified dialog box used to select language ("Language" option in "Options" menu) - also available from product selector dialog box --------------------------------------------------------------- Terminal selector --------------------------------------------------------------- - dialog box keeps previous selections when reopened - keeps previous "Keyboard" selection following new "Terminal selection" if applicable - jumps to "PC compatible" terminal selection if "PC compatible" selected in "Keyboard" box - updated ".cnd" terminal list files --------------------------------------------------------------- Preamble / postamble --------------------------------------------------------------- - added characters (availability depends on selected product) --------------------------------------------------------------- Data editing, Keyboard remapping, Scale solicitation (MicroBar 9730 / 9735) --------------------------------------------------------------- - added characters --------------------------------------------------------------- New products supported --------------------------------------------------------------- - Sabre 1551E - ScanPlus 1802 --------------------------------------------------------------- Setup files --------------------------------------------------------------- - modified for all products (version = 1999/11/15) - added different language versions for ScanPlus 1800 - renamed setup file and bitmap file for MaxiScan 1000 (were "ms1X00en.cmd" and "ms1X00.bmp", now "ms1000en.cmd" and "ms1000.bmp") (delete "ms1X00en.cmd" and "ms1X00.bmp" if already present in your EasySet directory due to previous installation) _______________________________________________________________ _______________________________________________________________ EasySet System Version 3.0.1 (build 12) - Update Patch _______________________________________________________________ --------------------------------------------------------------- Terminal selector --------------------------------------------------------------- - modified to make terminal file selection case-independent _______________________________________________________________ _______________________________________________________________ EasySet System Version 3.0.1 (build 5) - Update Patch _______________________________________________________________ --------------------------------------------------------------- Version info --------------------------------------------------------------- - added: right-click easyset.exe to view "Properties" - Version (already provided in "Help - About EasySet System ..." menu option) --------------------------------------------------------------- Interface --------------------------------------------------------------- - added Portuguese language option (new "language.txt" file) --------------------------------------------------------------- Terminal selector --------------------------------------------------------------- - corrected for interface numbers > 4095 - modified to support ScanPlus 1802 _______________________________________________________________ _______________________________________________________________ EasySet System Version 3.0.0 _______________________________________________________________ New Windows 32-bit version for Windows 95/98/NT --------------------------------------------------------------- Installation --------------------------------------------------------------- - InstallShield install/uninstall --------------------------------------------------------------- Execution --------------------------------------------------------------- - the "easyset.ini" file is now located in the EasySet directory (in previous versions of EasySet it was located in "c:\Windows") - the EasySet directory used at runtime is the directory where "easyset.exe" is located (in previous versions of EasySet, the runtime directory was specified in the "easyset.ini" file in "c:\Windows") - the status bar indicates the runtime directory used when you start up EasySet --------------------------------------------------------------- Added functions --------------------------------------------------------------- - Terminal selector (MaxiScan 2100, MicroBar 9730, ScanPlus 1800) - Data editing (replaces data reformatting function in previous versions), keyboard remapping, scale solicitation (MicroBar 9730) --------------------------------------------------------------- New products supported --------------------------------------------------------------- - MaxiScan 3100 _______________________________________________________________ _______________________________________________________________ EasySet System Version 2.02 _______________________________________________________________ --------------------------------------------------------------- MicroBar 9730 --------------------------------------------------------------- - corrected "data reformatting" function to allow creation of alphanumeric filter masks for Code 128 and some other symbologies (originally only numerical masks were accepted for these symbologies) _______________________________________________________________ _______________________________________________________________ EasySet System Version 2.01 _______________________________________________________________ --------------------------------------------------------------- ScanPlus S Series --------------------------------------------------------------- - removed "Terminal selector" function in order to simplify EasySet installation ("bdeinst" setup procedure not necessary for version 2.01 of EasySet) --------------------------------------------------------------- MicroBar 9730 --------------------------------------------------------------- - added "data reformatting" function _______________________________________________________________ _______________________________________________________________ EasySet System Version 2.00 _______________________________________________________________ --------------------------------------------------------------- ScanPlus S Series --------------------------------------------------------------- - added "Terminal selector" function - IMPORTANT: For version 2.00 of EasySet, you must perform the "bdeinst" setup procedure before you can use EasySet !!! BDE is necessary for the terminal selector function provided for ScanPlus S Series products. - bdeinst setup procedure: 1. - cd-rom: Go to the easyset\bdeinst\disk1 directory on the cd-rom. - diskettes: Open the bdeinst1 - disk1 diskette. - download from the Web / Lotus Notes: Extract bdeinst.zip to your disk (Use Folder Names option active) and go to the bdeinst\disk1 directory. 2. Run setup.exe. 3. Reboot your machine when setup is complete. 4. Go to the IDAPI directory and run bdecfg.exe. 5. Open the Alias page and click New Alias. 6. Enter the alias for your product (spss for ScanPlus S Series) and click OK. 7. Enter the pathname of your EasySet directory (example: c:\easyset) in the PATH field. 8. Save your BDE configuration (File - Save) and quit bdecfg.exe. 9. Run EasySet. ----------------------------- END ----------------------------